Getting Started with NI 7340/7350 Controllers and AKD Drives

|

© National Instruments

|

35

3.

Complete the following steps to configure the static IP based on your operating system 
version.

(Windows XP)

a.

Select 

Start»Control Panel»Network Connections

 to open the 

Network 

Connections 

dialog box.

b.

Select the network connection type corresponding to the port you used to connect the 
AKD servo drive. This will most likely be 

Local Area Connection 

x

, where x 

corresponds to the number of the connection.

c.

Click 

Properties 

to open the 

Local Area Connection Properties

 dialog box.

d.

Select 

Internet Protocol (TCP/IP)

 from the list and click 

Properties

.

e.

In the 

Internet Protocol (TCP/IP)

 dialog box, select 

Use the following IP address

.

f.

Change 

IP address

 to 

198.168.0.100

.

g.

Change 

Subnet mask

 to 

255.255.255.0

(Windows Vista or Later)

a.

Select 

Start»Control Panel»Network and Sharing Center.

b.

Select the network connection type corresponding to the port you used to connect the 
AKD servo drive. This will most likely be 

Local Area Connection

 

x

, where x 

corresponds to the number of the connection.

c.

Click 

Properties 

to open the 

Local Area Connection Properties

 dialog box.

d.

Select 

Internet Protocol Version 4 (TCP/IPv4)

 from the list and click 

Properties

.

e.

In the 

Internet Protocol Version 4 (TCP/IPv4)

 dialog box, select 

Use the following 

IP address

.

f.

Change 

IP address

 to 

198.168.0.100

.

g.

Change 

Subnet mask

 to 

255.255.255.0

Verify that S1 and S2 are set to non-zero values.

The Motor Responds Poorly

Use the Servo Tune tabs in MAX to change the control loop settings for the motor. Refer to 

Manually Tuning a System From Scratch

 topic in the 

Measurement & Automation Explorer Help 

for Motion

 for information about using the Servo Tune tabs to tune your motor.

Using an EtherCAT AKD Drive in Analog Mode

If you are using an EtherCAT AKD drive in Analog mode with firmware version 
M_01-04-00-003 or later, you must set FBUS.PARAM05 to 4. Complete the following steps to 
set this parameter.

1.

Click the 

Parameters

 tree icon to list all configurable drive parameters.

2.

Expand the 

Fieldbuses

 section.

3.

Set the FBUS.PARAM05 parameter to 4.

4.

Save all configuration changes to the drive by clicking the 

Save to Drive

 toolbar button 

shown in Figure 19.

Содержание PCI-7352

Страница 1: ...PCI 7352...

Страница 2: ...and Installation 8 Step 1 Connect and Configure the NI UMI 8 Step 2 Mount the Drive and Connect the Protective Earth 14 Step 3 Connect the NI UMI to AKD Cable to the AKD Servo Drive 15 Step 4 Connect...

Страница 3: ...ing items to get started Hardware A computer with an available PXI or PCI slot NI 7340 or NI 7350 motion controller UMI 7764 or UMI 7772 74 68 pin cable to connect your NI UMI and motion controller UM...

Страница 4: ...Visual C Microsoft Visual Basic AKD WorkBench software Figures 1 and 2 show the hardware connections using a UMI 7772 74 and UMI 7764 respectively Figure 1 UMI 7772 74 to AKD Drive Connections Host PC...

Страница 5: ...designing a basic move designing a multi axis move incorporating image and data acquisition into motion applications and working with common motion concepts such as contouring and breakpoints This doc...

Страница 6: ...ing steps to install the NI Motion driver software 1 Insert the NI Motion CD into the CD ROM drive to display the NI Motion installation screen 2 If you have autorun enabled autorun exe runs automatic...

Страница 7: ...e reverse order 6 Plug in and power on the chassis PCI Controllers 1 Power off and unplug the computer Caution To protect yourself and the computer from electrical hazards the computer must remain unp...

Страница 8: ...to the network using DHCP If DHCP is not available the controller connects to the network with a link local IP address Tip You can connect a monitor to the PXI to display startup messages such as the...

Страница 9: ...your VIs on the host and then download them to the remote system when you are ready All you need to change is the board ID in your VI from the locally assigned Board ID to the ID assigned by the remot...

Страница 10: ...Connector 25 pin DSUB connector containing encoder limit and home sensor signals UMI 7772 74 Control Connector 15 pin DSUB connector containing drive command and drive enable signals X8 10 Pin Connec...

Страница 11: ...Active Low Table 1 UMI 7772 74 to AKD Drive Cable Screw Terminal Pinout Pin Signal Name 1 Forward Limit 2 Home 3 Reverse Limit 4 COM 5 24 V OUT 6 COM 7 NC 8 NC 9 NC 10 Digital Ground 11 5 V Output 12...

Страница 12: ...e AKD servo drive 4 Connect the positive lead of the 24 V external power supply to the V terminal and the negative lead to the C terminal then connect the V terminal to the Viso terminal and the C ter...

Страница 13: ...n the NI 7340 7350 motion controller and the Motion I O connector on the UMI 7764 2 Connect the UMI 7764 to AKD Drive cable to the UMI 7764 by connecting the leads from the cable to the correct screw...

Страница 14: ...olarity configuration for the AKD servo drive Inhibit Input S2 Active High Inhibit Output S1 Active Low The UMI 7764 DIP switch configuration is shown in Figure 7 Figure 7 UMI 7764 Inhibit Input and I...

Страница 15: ...n the drive BP4 BP3 BP2 BP1 GND 5 V TRIG4 TRIG3 TRIG2 TRIG1 ASSY186343A 01 UMI 7764 FWDLIM1 HOME1 REVLIM1 INHIN1 GND AOUT1 AOGND INHOUT1 STEP CW 1 DIR CCW 1 5 V GND ENCA1 ENCA1 ENCB1 ENCB1 INDEX1 INDE...

Страница 16: ...vo drive Refer to Figure 9 for the location of the connectors Figure 9 AKD Servo Drive Connectors 1 24 V Supply STO X1 2 Motor Brake X2 3 AC Input Power X3 4 Encoder Emulation X9 5 Drive Grounding Lug...

Страница 17: ...ect the 24 V power supply terminal to the 24V connection on the X1 3 pin connector 2 Connect the 24 V power supply return terminal to the GND connection on the X1 3 pin connector The X1 connector is c...

Страница 18: ...ower supply to the UMI 7764 to AKD cable Figure 6 shows the UMI 7764 to AKD Drive Cable 24V power supply leads Note Do not plug in or turn on the 24 V power supply until after you complete Step 7 Conn...

Страница 19: ...he STO and 24V wires are internally connected in the UMI 7774 to AKD cable You must insulate the STO wire if you disconnect it from the X1 connector 2 Connect the STO terminal and GND terminal to the...

Страница 20: ...r the location of the connectors 1 Connect the motor 6 pin connector to the AKD servo drive X2 motor connector Note The X2 connector also provides connection for the drive to control the 24 V holding...

Страница 21: ...g these terminals Note Do not turn on AC power until after you complete Step 7 Connect the Drive Communication in the NI UMI and AKD Servo Drive Configuration and Installation section Figure 13 shows...

Страница 22: ...ips and Troubleshooting section for instructions about direct connection using a static IP address 1 Set S1 and S2 on the drive to 0 to configure the drive for DHCP mode The drive obtains an IP addres...

Страница 23: ...hes in the LED indicators Figure 9 shows the location of the LED indicators on the AKD servo drive a b c Drive IP address flashed sequentially d Drive status either current operation mode or the fault...

Страница 24: ...ick the MAX icon on the desktop or select Start All Programs National Instruments Measurement Automation to open MAX 2 Expand Devices and Interfaces and then expand NI Motion Devices in the configurat...

Страница 25: ...une Main tab to tune the control loop settings and determine the relative stability of the servo axis Refer to Manually Tuning a System From Scratch in the Measurement Automation Explorer Help for Mot...

Страница 26: ...the AKD servo drive and is also available from ni com updates Complete the following steps to install AKD WorkBench 1 Insert the AKD WorkBench CD in the CD ROM drive 2 Double click Full Setup exe to...

Страница 27: ...com Getting Started with NI 7340 7350 Controllers and AKD Drives Figure 18 shows the AKD WorkBench start page Figure 18 AKD WorkBench Start Page 1 Available Drives 2 Specify Address 3 Connect to Drive...

Страница 28: ...AKD WorkBench Overview Page 4 Configure the command source and operation mode a Open the Settings page and set the Command Source to 3 Analog b Set the Operation Mode to 0 Torque Mode 1 Software Enabl...

Страница 29: ...ines rev Note The encoder resolution output value determines the equivalent resolution of an incremental encoder in pulses per revolution PPR A resolution of 2 000 lines rev is the same as 8 000 quadr...

Страница 30: ...rkBench Encoder Emulation page Figure 21 AKD WorkBench Encoder Emulation Page 6 Configure the analog input command scaling a Expand the Settings tree item and open the Motor page b Write down the moto...

Страница 31: ...page Figure 22 AKD WorkBench Motor Page c Expand the Settings tree item and open the Analog Input page d Set the Scale to the appropriate Arms V value based on the following equation Scale Motor cont...

Страница 32: ...gure 23 shows the analog input scaling setting Figure 23 AKD WorkBench Analog Input Scale Setting 7 Configure the software enable signal a Click the Parameters tree icon to list all configurable drive...

Страница 33: ...de refer to Using an EtherCAT AKD Drive in Analog Mode in the Tips and Troubleshooting section for additional settings you may need to apply 8 Activate the software enable on the drive by clicking the...

Страница 34: ...e your motion system setup by connecting and configuring additional I O such as limits as required by your application If using the UMI 7764 use the available screw terminal connections on the same ax...

Страница 35: ...ommunicate With the Drive Using Ethernet Confirm that the link LEDs on the drive and PC are both illuminated Figure 16 shows the location of the link LED on the drive UMI 7772 74 Does Not Turn On Conf...

Страница 36: ...rea Connection x where x corresponds to the number of the connection c Click Properties to open the Local Area Connection Properties dialog box d Select Internet Protocol Version 4 TCP IPv4 from the l...

Страница 37: ...ftware Manually enter the drive IP address by enabling the Specify Address checkbox on the AKD WorkBench software Start Page shown in Figure 18 To obtain the drive IP address either press the B1 butto...

Страница 38: ...GITAL OUT2 DIGITAL OUT2 DIGITAL OUT1 DIGITAL IN6 NSTOP AGND DGND DGND Fault Feedback Thermal Control Included Reference Safety Instructions and Use As Directed Br RB DC L1 L2 L3 PE 24V STO GND RB DC B...

Страница 39: ...an Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your produ...

Страница 40: ...ted States and other countries Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technolog...

Отзывы: