© National Instruments
|
7-3
Table 7-1.
STATUS LED Indications
LED
Behavior
LED
Color
Indication
Solid
Green
The smart camera initialized successfully and is ready for use.
1 Flash
Green
The smart camera IP address or software is unconfigured. The
smart camera ships from the factory unconfigured. The smart
camera also enters the unconfigured state if it is configured for
DHCP and no DHCP server is available. Use MAX or Vision
Builder AI to configure the smart camera. Refer to the
section of Chapter 2,
information about configuring the smart camera.
2 Flashes
Green
The smart camera detects an error in the software configuration.
The camera has automatically started up into safe mode, regardless
of the SAFE MODE DIP switch position. This usually occurs when
an attempt to upgrade the software is interrupted or if system files
are deleted from the smart camera. Reinstall software on the smart
camera. Refer to the
Install Software on the NI Smart Camera
section of Chapter 2,
installing software on the smart camera.
3 Flashes
Green
The smart camera is in safe mode because the SAFE MODE DIP
switch is in the ON position. Refer to the
section for information about the SAFE MODE DIP switch.
4 Flashes
Green
The smart camera has experienced two consecutive software
exceptions. The smart camera automatically restarts after an
exception. After the second exception, the smart camera remains in
the exception state, alerting you to resolve the problem. Reinstall
software on the smart camera or contact National Instruments for
assistance. Refer to the
Install Software on the NI Smart Camera
section of Chapter 2,
5 Flashes
Green
The smart camera detects a critical error. Reinstall software on
the smart camera or contact National Instruments for assistance.
Refer to the
Install Software on the NI Smart Camera
section of
Chapter 2,
, for information about installing
software on the smart camera.
Flashing
Red
The smart camera detects a software crash or hang.
Contact National Instruments for assistance.
Solid
Red
The smart camera detects a critical firmware error. Contact
National Instruments for assistance.
Содержание NI Vision 17 Series
Страница 1: ...ISC 1752...