background image

If the installation window does not appear, navigate to the drive, double-click it, and
double-click 

autorun.exe

.

6.

Follow the instructions in the installation prompts.

Note

 

Windows users may see access and security messages during

installation. Accept the prompts to complete the installation.

Note

 

The default installation installs NI LabVIEW Instrument Design

Libraries for Vector Signal Transceivers, NI-RFmx, NI-RFSA, and NI-RFSG.

7.

When the installer completes, select 

Restart

 in the dialog box that prompts you to restart,

shut down, or restart later.

Installing the NI 5645R

Caution

 

To prevent damage to the NI 5645R caused by ESD or contamination,

handle the module using the edges or the metal bracket.

You must install the software before installing the hardware.

Before you install the hardware, refer to the guidelines in the 

Maintain Forced-Air Cooling

Note to Users

 included with the module to ensure that the device can cool itself effectively.

This document is also available at 

ni.com/manuals

.

The NI 5645R is a four-slot module with two backplane connectors. The module must be
installed into four adjacent chassis slots, and the left two slots must be PXI Express
compatible.
1.

Ensure the AC power source is connected to the chassis before installing the module.

The AC power cord grounds the chassis and protects it from electrical damage while you
install the module.

2.

Power off the chassis.

3.

Inspect the slot pins on the chassis backplane for any bends or damage prior to
installation. Do not install a module if the backplane is damaged.

4.

If the chassis has multiple fan speed settings, ensure the fans are set to the highest setting.

Note

 

Inadequate air circulation could cause the temperature inside the chassis

to rise above the optimal operating temperature for the device, potentially
causing thermal shutdown, shorter lifespans, or improper performance.

5.

Position the chassis so that inlet and outlet vents are not obstructed.

Caution

 

Do not disconnect the cable that connects CAL IN to CAL OUT.

Removing the cable from or tampering with the CAL IN or CAL OUT front
panel connectors voids the product calibration and specifications are no longer
warranted.

6.

Remove the black plastic covers from all the captive screws on the module front panel.

7.

Identify a supported slot in the chassis. The following figure shows the symbols that
indicate the slot types.

8

  | 

ni.com

  | 

NI PXIe-5645R Getting Started Guide

Содержание NI PXIe-5645R

Страница 1: ...ovided by this equipment may be impaired if it is used in a manner not described in the documentation Contents Electromagnetic Compatibility Guidelines 2 Verifying the System Requirements 2 Unpacking the Kit 2 Preparing the Environment 3 Verifying the Kit Contents 4 Other Equipment 4 Choosing and Installing the Software 5 Software Options 5 Installing the Software 7 Installing the NI 5645R 8 Direc...

Страница 2: ...documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Caution To ensure the specified EMC performance operate this product only with cables less than 3 ...

Страница 3: ...e that the environment you are using the NI 5645R in meets the following specifications Operating ambient temperature IEC 60068 2 1 IEC 60068 2 2 0 C to 55 C Operating relative humidity IEC 60068 2 56 10 to 90 noncondensing Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Caution Clean the hardware with a soft nonmetallic brush or lint free cloth Mak...

Страница 4: ...d Air Cooling Note to Users 7 NI PXIe 5645R Getting Started Guide Other Equipment There are several required items not included in your device kit that you need to operate the NI 5645R Your application may require additional items not included in your kit to install or operate your device Required Items A PXI Express chassis and chassis documentation The NI PXIe 1075 chassis is one available optio...

Страница 5: ...are Software Options NI provides three software options for programming the NI 5645R NI RFmx NI RFSA and NI RFSG instrument driver software and the instrument design libraries NI PXIe 5645R Getting Started Guide National Instruments 5 ...

Страница 6: ...Q data Use NI RFSG to generate continuous or modulated waveforms Use NI RFSA and NI RFSG with the NI Modulation Toolkit to develop software defined radio transmitters and receivers Use NI RFSG with the NI Modulation Toolkit to create and generate modulated signals to test receivers Instrument design libraries The instrument design libraries allow you to customize your NI 5645R device to suit the n...

Страница 7: ...NI RFSA and NI RFSG Soft Front Panels support Yes Yes Yes LabVIEW examples or sample projects Includes LabVIEW examples Includes LabVIEW examples Includes LabVIEW sample projects with additional examples available at ni com vstgettingstarted Installing the Software You must be an Administrator to install NI software on your computer 1 Install NI LabVIEW 2 Recommended Install NI LabVIEW FPGA Module...

Страница 8: ...jacent chassis slots and the left two slots must be PXI Express compatible 1 Ensure the AC power source is connected to the chassis before installing the module The AC power cord grounds the chassis and protects it from electrical damage while you install the module 2 Power off the chassis 3 Inspect the slot pins on the chassis backplane for any bends or damage prior to installation Do not install...

Страница 9: ...it into the empty compatible slots Ensure the base engages with the guides in the chassis Figure 3 NI 5645R Module Installation 1 2 3 1 PXI Express Chassis 2 NI PXIe 5645R Module 3 Ejector Handle in Down Position 11 Latch the module in place by pulling up on the ejector handle 12 Secure the module front panel to the chassis using the front panel mounting screws Note Tightening the top and bottom m...

Страница 10: ...device is powered off may cause damage Ensure you are properly grounded when manipulating cables or antennas connected to the NI 5645R RF IN connector If you are using nonisolated devices such as a nonisolated RF antenna ensure the devices are maintained in a static free environment If you are using an active device such as a preamplifier or switch routed to the NI 5645R RF IN connector ensure tha...

Страница 11: ... Ω PFI 0 LVTTL DIGITAL I O LVTTL I I Q Q I I Q Q RF IN 33 dBm MAX 50 Ω CAL IN LO OUT 0 dBm 50 Ω LO IN 15 dBm MAX 50 Ω LO IN 15 dBm MAX 50 Ω LO OUT 0 3 dBm 50 Ω CAL OUT RF OUT Reverse Power 33 dBm MAX 50 Ω RF IN 0 RF OUT 0 I Q IN 0 DIFF 2Vp p SE 2Vp p 50 Ω I Q OUT 0 DIFF 1Vp p SE 0 5Vp p 50 Ω ESD SENSITIVE ACCESS ACTIVE NI PXIe 5645R Getting Started Guide National Instruments 11 ...

Страница 12: ...Hz Reference Clock REF OUT Output terminal that can export a 10 MHz Reference Clock or the 120 MHz Sample Clock PFI 0 Programmable function digital I O DIO connector for use with triggers or events DIGITAL I O DIO terminal that contains general purpose 3 3 V LVTTL DIO signals DIO lines are direction configurable as input or output Table 5 NI 5645R RF Front Panel Connectors Connector Use RF IN 0 RF...

Страница 13: ...s Connector Use Terminal Configuration Differential Single ended I Q IN 0 I Input terminal for in phase signals Positive terminal Input signal terminal I Input terminal for in phase signals Negative terminal Requires 50 Ω termination Q Input terminal for quadrature signals Positive terminal Input signal terminal Q Input terminal for quadrature signals Negative terminal Requires 50 Ω termination I ...

Страница 14: ...reen The device is generating a waveform Dim amber The device is waiting for an acquisition Reference Trigger Solid amber The device is acquiring a waveform Solid red The device has detected an error The LED remains red until the error condition is removed Note The indicators are listed in increasing order of priority For example if you are generating a waveform using NI RFSG and waiting on an acq...

Страница 15: ...Perform a complete self calibration after first installing your module and letting it warm up for 30 minutes Note Warm up begins when the PXI Express chassis has been powered on and the operating system has completely loaded The NI 5645R modules are externally calibrated at the factory however you should perform a self calibration in any of the following situations After first installing the NI 56...

Страница 16: ...ctory and import library files located in one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit NIDir Shared ExternalCompilerSupport C include Windows 10 64 bit 8 1 64 bit 7 64 bit 32 bit installation NIDir Shared ExternalCompilerSupport C lib32 msvc 64 bit installation NIDir Shared ExternalCompilerSupport C lib64 msvc where NIDir is one of the following locations Windows 10 32 bi...

Страница 17: ...es x86 IVI Foundation IVI Microsoft Visual C C Use the header files located in the IVIROOTDIR32 Include directory and import library files located in the IVIROOTDIR32 Lib directory where IVIROOTDIR32 is one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit Program Files IVI Foundation IVI Windows 10 64 bit 8 1 64 bit 7 64 bit Program Files x86 IVI Foundation IVI Microsoft NET To u...

Страница 18: ...located in the IVIROOTDIR32 Lib directory where IVIROOTDIR32 is one of the following directories Windows 10 32 bit 8 1 32 bit 7 32 bit Program Files IVI Foundation IVI Windows 10 64 bit 8 1 64 bit 7 64 bit Program Files x86 IVI Foundation IVI Microsoft NET To use the NET API you must install the NET class libraries For download and installed file locations visit ni com info and enter Info Code NET...

Страница 19: ...mming the NI 5645R 1 Launch LabVIEW 2 In the New Project dialog box select Sample Projects in the left pane 3 Navigate to and open the project that best matches your application requirements Using Microsoft Visual C C If you re using NI RFmx or NI RFSA with Microsoft Visual C C locate examples in the following directories Table 9 Location of Microsoft Visual C C Programming Examples Software Optio...

Страница 20: ...z continuous wave CW tone RF signal at the RF output terminal of your device 5 Select Start All Programs National Instruments NI RFSA NI RFSA Soft Front Panel to launch the NI RFSA Soft Front Panel 6 Select the device identifier assigned to the NI 5645R in MAX in the Device drop down menu 7 Verify that the NI RFSA Soft Front Panel is receiving the CW tone 8 Close the NI RFSA Soft Front Panel and N...

Страница 21: ...Disconnect any signals from the PXI Express module front panels Caution Do not disconnect the cable that connects CAL IN to CAL OUT Removing the cable from or tampering with the CAL IN or CAL OUT front panel connectors voids the product calibration and specifications are no longer warranted 2 Power off the PXI Express chassis 3 Remove the module from the PXI Express chassis and inspect it for dama...

Страница 22: ... controller verify that a National Instruments entry appears in the system device list If error conditions appear in the list right click the NI PXIe 5645R and NI RIO FPGA Device nodes and select Update Driver If you are using an MXI controller right click PCI to PCI Bridge and select Properties from the shortcut menu to verify that the bridge is enabled 6 Restart your computer 22 ni com NI PXIe 5...

Страница 23: ...y Support ni com support more about your products through ni com Located online at ni com manuals Located online at ni com gettingstarted RF Solutions ni com rf NI PXIe 5645R Specifications NI RF Vector Signal Transceivers Help Tip The NI RF Vector Signal Transceivers Help is an HTML version of a traditional user manual that includes detailed information about RF fundamentals device features and p...

Страница 24: ...nformation support phone numbers email addresses and current events Refer to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering NI products technology refer to the appropriate location Help Patents in your software the patents tx...

Отзывы: