30 V, 2 A
1 × 10
5
cycles
............................................................
60 VDC, 1 ADC resistive
1 × 10
5
cycles
Note
Relays are field replaceable. Refer to the NI Switches Help at
for more information about replacing a failed relay.
Physical Characteristics
............................................................................
Relay type
Electromechanical, non-latching
............................................................................
Relay contact material
Palladium-ruthenium, gold covered
............................................................................
Front panel connector
160 DIN 41612, 160 positions, male
Power requirement
PXI Express
............................................................
12 V
21 W
............................................................
3.3 V
3.4 W
............................................................................
Dimensions (L × W × H)
3U, one slot, PXI/cPCI module, PXI Express
compatible 21.6 cm × 2.0 cm × 13.0 cm
(8.5 in. × 0.8 in. × 5.1 in.)
............................................................................
Weight
230 g (8.1 oz)
Environment
............................................................................
Maximum altitude
2,000 m (800 mbar) (at 25 °C ambient
temperature)
............................................................................
Pollution Degree
2
Indoor use only.
Operating Environment
............................................................................
Ambient temperature range
0 °C to 55 °C (Tested in accordance with
IEC 60068-2-1 and IEC 60068-2-2. Meets
MIL-PRF-28800F Class 3 low temperature
limit and MIL-PRF-28800F Class 2 high
temperature limit.)
............................................................................
Relative humidity range
10% to 90%, noncondensing (Tested in
accordance with IEC 60068-2-56.)
4
|
ni.com
|
NI PXIe-2526 Specifications
Содержание NI PXIe-2526
Страница 1: ...PXIe 2526...