ni.com

Complete the following steps to install the necessary components from the 
NI Device Drivers CD.

1.

Log onto the computer as an administrator or as a user with 
administrative privileges.

2.

Insert the NI Device Drivers CD (for LabVIEW 7.0 or later) into the 
CD drive.

3.

Run 

setup.exe

 from the NI Device Drivers CD.

4.

Follow the instructions that appear on the screen until you reach the 
Feature Tree window.

5.

In the Feature Tree window, you can select the components to install. 
You must install all the components for NI-VISA, NI-RIO, and 
NI Measurement & Automation Explorer. You also can install other 
components.

6.

Complete the driver installation and remove the NI Device Drivers CD.

7.

You must shut down your computer before installing any hardware.

Unpacking

The RIO device is shipped in an antistatic package to prevent electrostatic 
damage to the device. Electrostatic discharge (ESD) can damage several 
components on the device.

Caution

Never

 touch the exposed pins of connectors.

To avoid such damage when handling the devices, take the following 
precautions:

Ground yourself using a grounding strap or by holding a grounded 
object.

Touch the antistatic package to a metal part of the computer chassis 
before removing the devices from the package.

Remove the devices from the package and inspect the devices for loose 
components or any other sign of damage. Notify NI if the devices appear 
damaged in any way. Do

 not

 install damaged devices into the computer.

Store the NI PXI-7831R in the antistatic envelope when not in use.

Содержание NI PXI-7831R

Страница 1: ...ereas traditional multifunction I O MIO devices have a fixed functionality provided by an application specific integrated circuit ASIC You can change the functionality of the FPGA on the RIO device by...

Страница 2: ...PCI embedded controller running Windows 2000 XP or any computer running Windows 2000 XP and a MXI 3 link to a PXI CompactPCI chassis At least one cable and terminal block for connecting signals to the...

Страница 3: ...e configured on a network The following documents are included on the NI Device Drivers CD and are also available at ni com manuals optional LabVIEW FPGA Module Release Notes LabVIEW FPGA Module User...

Страница 4: ...tion and remove the NI Device Drivers CD 7 You must shut down your computer before installing any hardware Unpacking The RIO device is shipped in an antistatic package to prevent electrostatic damage...

Страница 5: ...e there are no lighted LEDs on the chassis If any are lit wait until they go out before continuing the installation 4 Remove the filler panel for the peripheral slot that you chose 5 Ground yourself u...

Страница 6: ...I lines eight AO lines and 16 DIO lines Figure 1 shows the I O connector locations for the NI PXI 7831R The I O connectors are numbered starting at zero The text in parentheses indicates whether each...

Страница 7: ...ND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND DGND 5V 5V DIO28 DIO30 DIO32 DIO34 DIO36 DIO38 DIO0 DIO2 DIO3 DIO5 DIO6 DIO7 DIO8 DIO1 DIO4 DIO9 DIO10...

Страница 8: ...ns guide you through running a simple example on the PXI 7831R Running this example confirms that you have installed your software and hardware correctly and it provides a brief introduction to using...

Страница 9: ...ponds to the voltage input If you do not have a signal source available connect AI1 and AI1 both to ground and confirm that the number returned by the AI 1 indicator is close to 0 10 The Loop Period c...

Страница 10: ...ion on the 1 RIO Board Host VI block diagram using the selection tool This opens the front panel for the Default 7831R FPGA VI Refer to the context help for the Default 7831R FPGA VI for more informat...

Отзывы: