manualshive.com logo in svg
background image

©

 National Instruments Corporation

3

NI PCIe-8255R User Manual

If the device is rated for use with hazardous voltages (>30 V

rms

, 42.4 V

pk

or 60 V

dc

), it may require a safety earth-ground connection wire. Refer to 

the device specifications for maximum voltage ratings.

Because of the danger of introducing additional hazards, do 

not

 install 

unauthorized parts or modify the device. Use the device only with the 
chassis, modules, accessories, and cables specified in the installation 
instructions. All covers and filler panels 

must

 be installed while operating 

the device.

Do 

not

 operate the device in an explosive atmosphere or where flammable 

gases or fumes may be present. Operate the device only at or below the 
pollution degree stated in the specifications. Pollution consists of any 
foreign matter—solid, liquid, or gas—that may reduce dielectric strength 
or surface resistivity. The following is a description of pollution degrees.

Pollution Degree 1—No pollution or only dry, nonconductive 
pollution occurs. The pollution has no effect.

Pollution Degree 2—Normally only nonconductive pollution occurs. 
Occasionally, nonconductive pollution becomes conductive because of 
condensation.

Pollution Degree 3—Conductive pollution or dry, nonconductive 
pollution occurs. Nonconductive pollution becomes conductive 
because of condensation.

Clean the device and accessories by brushing off light dust with a soft, 
nonmetallic brush. Remove other contaminants with a stiff, nonmetallic 
brush. The unit 

must

 be completely dry and free from contaminants before 

returning it to service.

You

 must

 insulate signal connections for the maximum voltage for which 

the device is rated. Do 

not

 exceed the maximum ratings for the device. 

Remove power from signal lines before connection to or disconnection 
from the device. 

Caution

National Instruments measurement products may be classified as either 

Measurement Category I or II. Operate products at or below the Measurement Category 
level specified in the hardware specifications.

Measurement Category

1

: Measurement circuits are subjected to working 

voltages

2

 and transient stresses (overvoltage) from the circuit to which they 

are connected during measurement or test. Measurement Category 
establishes standardized impulse withstand voltage levels that commonly 

1   

Measurement Categories as defined in electrical safety standard IEC 61010-1.

2   

Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.

Содержание NI PCIe-8255

Страница 1: ...are Release Notes Computer running Windows 2000 XP with at least one PCIe slot IEEE 1394 camera 9 pin IEEE 1394 cable for interfacing to IEEE 1394b cameras 6 pin to 9 pin cable or 6 pin to 9 pin adapt...

Страница 2: ...afety Information Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in...

Страница 3: ...mes conductive because of condensation Pollution Degree 3 Conductive pollution or dry nonconductive pollution occurs Nonconductive pollution becomes conductive because of condensation Clean the device...

Страница 4: ...s on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets i...

Страница 5: ...are Release Notes for installation and configuration instructions 2 Power off and unplug the computer Caution To protect yourself and the computer from electrical hazards the computer must remain unpl...

Страница 6: ...and gently rock the NI 8255R into the slot The connection may be tight but do not force the device into place Note Check that the bracket of the NI 8255R lines up with the hole in the back panel rail...

Страница 7: ...nnector on the NI 8255R front panel Refer to Figure 2 for the location of the IEEE 1394b bilingual connectors on the NI 8255R If you are using an IEEE 1394a cable an IEEE 1394a to IEEE 1394b adapter i...

Страница 8: ...ou are using a power supply other than the NI desktop power supply skip this step and proceed to step 2 a Disconnect the 4 position power connector from the power supply as shown in Figure 3 Figure 3...

Страница 9: ...I Vision I O Terminal Block and Prototyping Accessory Refer to Table 1 for a summary of the isolated power supply connections 3 Optional To suppress electromagnetic interference install a ferrite on t...

Страница 10: ...sign resources to it Use Measurement Automation Explorer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8255R for acquisition Note You must in...

Страница 11: ...z Minimum pulse detected 500 ns Power on state Input high impedance 61 9 k pull up to 5V 1 The bus power specification assumes that power is provided to the NI 8255R device from the host computer powe...

Страница 12: ...V Turn on current 7 1 mA typical 14 mA maximum Maximum pulse rate 100 kHz Minimum pulse detected 10 s Reverse polarity protection Yes 30 V Isolated Current Sourcing Outputs Number of channels 4 On st...

Страница 13: ...x4 x8 x16 Physical Characteristics Dimensions 11 2 cm 16 8 cm 4 4 in 6 6 in Weight 130 g 4 5 oz Environment The NI 8255R device is intended for indoor use only Operating temperature 0 C to 55 C Storag...

Страница 14: ...ons Class A Note For EMC compliance operate this device with shielded cabling CE Compliance The NI 8255R meets the essential requirements of applicable European Directives as amended for CE marking as...

Страница 15: ...as offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or d...

Страница 16: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Отзывы: