Appendix A
Specifications
©
National Instruments Corporation
A-11
Environmental
Operating temperature............................ 0 to 45 °C
Storage temperature ............................... –20 to 70 °C
Humidity ................................................ 5 to 90% RH, noncondensing
Maximum altitude .................................. 2000 m
Pollution Degree (indoor use only) ........ 2
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 3111-1, UL 61010B-1
•
CAN/CSA C22.2 No. 1010.1
Note
For UL and other safety certifications, refer the the product label or to
ni.com
.
Electromagnetic Compatibility
Emissions ............................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity ................................................ EN 61326:1997 + A2:2001,
Table 1
EMC/EMI............................................... CE, C-Tick, and FCC Part 15
(Class A) Compliant
Note
For EMC compliance, you
must
operate this device with shielded cabling.