Chapter 1
Hardware Overview and Installation
©
National Instruments Corporation
1-5
NI 177x Smart Camera User Manual
Connect to the Development Computer
The NI 177x Smart Camera can connect to the development computer
directly or through a network. To configure the NI 177x Smart Camera
through a network, the NI 177x Smart Camera and the development
computer must be connected to the same subnet.
Caution
To prevent data loss and to maintain the integrity of your Ethernet installation, do
not use a cable longer than 100 m. National Instruments recommends using a shielded
twisted pair cable for maximum signal integrity.
Direct Connection
To connect the NI 177x Smart Camera directly to the development
computer, complete the following steps.
1.
Connect the 8-pin female M12 connector to the 100/1G connector on
the NI 177x Smart Camera.
2.
Connect the Ethernet connector to an Ethernet port on the development
computer.
The NI 177x Smart Camera is now connected directly to the development
computer.
Network Connection
To connect the NI 177x Smart Camera to the development computer
through a network, complete the following steps.
1.
Verify that the development computer is connected to the network and
powered on.
2.
Connect the 8-pin female M12 connector to the 100/1G connector on
the NI 177x Smart Camera.
3.
Connect the Ethernet connector to an Ethernet port.
The NI 177x Smart Camera is now connected through a network and is
available for additional configuration with the development computer.