National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
4.2.2 PFI 1-4 Tab
The purpose of the PFI 1-4 tab is to enable individual PFI Driver PFI channels 1-4, and configure current control
parameters.
PFIX_FirstPeak
Tip Strip: Causes phase 2 to begin after current reaches first peak
Detail: A software option of the PFI Driver module to transfer operation from the first phase to the second
phase upon reaching the first current peak corresponding to the first phase current setpoint. The first phase
duration should be set to a minimum value long enough for the first peak to be reached.