
National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
RailP
Tip Strip: Rail pressure in bar
Units: bar
Detail: Rail pressure used as feedback to the PID controller. The analog channel utilized for pressure
. The analog channel must be converted to units of bar via the
Analog Input Setup window.
RailP_ControlMode
Tip Strip: Selects the IMV or HPV as controlled by PID
Detail: Selects between
IMV PID Mode
or
HPV PID Mode
. When in
IMV PID Mode
, the HPV PID control
parameters will be disabled (grayed out) and the HPV will be controlled by a constant duty cycle and
frequency. When in
HPV PID Mode
, the IMV PID control parameters will be disabled (grayed out) and the
IMV will be controlled by a constant duty cycle and frequency.
Clear RailP Fault
Tip Strip: Clears faults related to rail pressure control
Detail: Clears
after the fault has been resolved.
RPC Plot
Tip Strip: Opens a plot window of
.