![National Instruments NI-CAN Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/national-instruments/ni-can/ni-can_user-manual_3506864066.webp)
Appendix B
Windows 98/95: Troubleshooting and Common Questions
B-4
ni.com
resource that caused the conflict and refer to the
Microsoft Windows User’s
Guide
for instructions on how to use the Device Manager to reserve
memory resources for legacy boards. After the conflict has been resolved,
run the NI-CAN Diagnostic utility again.
Interrupt Resource Conflict
This error occurs if the interrupt resource assigned to a CAN interface
conflicts with the interrupt resources being used by other devices in the
system. Resource conflicts typically occur when your system contains
legacy boards that use resources that have not been reserved properly with
the Device Manager. If a resource conflict exists, write down the interrupt
resource that caused the conflict and refer to the
Microsoft Windows User’s
Guide
for instructions on how to use the Device Manager to reserve
interrupt resources for legacy boards. After the conflict has been resolved,
run the NI-CAN Diagnostic utility again.
NI-CAN Software Problem Encountered
This error occurs if the NI-CAN Diagnostic utility detects that it is unable
to communicate correctly with the CAN hardware using the installed
NI-CAN software. If you get this error, shut down your computer, restart it,
and run the NI-CAN Diagnostic utility again. If the problem persists, try
reinstalling the NI-CAN software.
Missing CAN Interface
If a National Instruments CAN interface is physically installed in your
system, but is not listed in the NI-CAN Diagnostic utility, check the
Windows Device Manager to see if Windows 98/95 has detected the
hardware. For more information, refer to the
section, earlier in this appendix.
CAN Hardware Problem Encountered
This error occurs if the NI-CAN Diagnostic utility detects a defect in the
CAN hardware. If you get this error, write down the numeric code shown
with the error, and contact National Instruments. Depending on the cause
of the hardware failure, National Instruments may need to upgrade your
CAN interface.