Figure 14.  

Mesh Configuration Example

In this configuration, R

1

 (a router) and R

2

 (a router) both communicate directly with the gateway. 

Measurements taken by both devices can directly reach the gateway without having to hop through 
another node. However, the configuration above does not always mesh in the same way. Figure 15 shows 
another possible configuration for the same network.

R

1

G

R

2

Содержание NI 9792

Страница 1: ...derutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In s...

Страница 2: ...tions The NI 9792 WSN Real Time Gateway combines with NI WSN 32xx nodes to form a wireless sensor network Figure 1 shows the NI WSN system components Figure 1 NI WSN System Components 1 PC or NI Real...

Страница 3: ...NI 9792 WSN Real Time Gateway User Guide and Specifications 2 ni com The NI 9792 WSN Real Time Gateway is shown in Figure 2 Figure 2 NI 9792 WSN Real Time Gateway...

Страница 4: ...using NI WSN products Caution Do not substitute parts or modify the NI WSN product Use the product only with the devices accessories and cables specified in the installation instructions Caution Do no...

Страница 5: ...cially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronic...

Страница 6: ...to a test object or if the product is used in residential areas To minimize the potential for the product to cause interference to radio and television reception or to experience unacceptable perform...

Страница 7: ...communications and hardware details simplifying programmatic access to I O channels The NI WSN software is on the software installation disc included with your NI 9792 WSN gateway device The NI WSN s...

Страница 8: ...spect them Contact NI if the devices appear damaged Do not install a damaged device Caution The device is static sensitive Always properly ground yourself and the equipment when handling or connecting...

Страница 9: ...ction of the NI WSN product page at ni com Caution If the ambient temperature is above 60 C you must mount the NI 9792 on a thermally conductive material Measure the ambient temperature at each side o...

Страница 10: ...NI 9792 WSN Real Time Gateway User Guide and Specifications 9 ni com Figure 5 NI 9792 Panel Mount Dimensions Template 114 3 mm 4 500 in 45 69 mm 1 799 in 55 91 mm 2 201 in 101 6 mm 4 000 in...

Страница 11: ...To mount the device on a DIN rail complete the following steps 1 Fasten the DIN rail clip to the device using a number 1 Phillips screwdriver and four 4 40 machine screws The screws are included in th...

Страница 12: ...six number 8 or M4 screws Refer to Figure 5 for the mounting hole template Setting Up the NI 9792 Device Complete the following steps to prepare the NI 9792 device for use 1 Before connecting the hard...

Страница 13: ...tarted Guide is available after installation from Start All Programs National Instruments NI WSN Make sure the NI 9792 device power is disconnected 5 Attach a ring lug as shown in Figure 9 to a 14 AWG...

Страница 14: ...o assign an IP address or reassign a static IP address for the subnet where you want it to be and physically move it to the other subnet The first time you configure the NI 9792 you must also install...

Страница 15: ...he power connector is plugged into the NI 9792 or while the power supply is on Powering On the NI 9792 Turn on each power supply to the NI 9792 system The NI 9792 runs a power on self test POST During...

Страница 16: ...W Real Time Software Wizard 9 Install LabVIEW Real Time software and device drivers on the NI 9792 After software installation the NI 9792 automatically reboots You can now program it using LabVIEW Re...

Страница 17: ...s such as displays or input devices Use the Serial VIs to read from and write to the serial port For more information about the Serial VIs refer to the LabVIEW Help Figure 12 NI 9792 RS 232 Serial Por...

Страница 18: ...ng operation Configuring DIP Switches Figure 13 NI 9792 DIP Switches All of the DIP switches are in the OFF position when the NI 9792 is shipped from National Instruments SAFE MODE Switch The position...

Страница 19: ...92 to reset the IP address and other TCP IP settings of the NI 9792 to the factory defaults Refer to the Resetting the Network Configuration section for more information about resetting the IP address...

Страница 20: ...e listed in Table 2 Table 2 LED State Device Status LED Description Color LED State Device Status 10 100 Green On Connected at 100 Mbps Off No Ethernet connection or 10 Mbps connection LINK ACT Green...

Страница 21: ...mation about installing software on the gateway 3 Blinks The gateway is in safe mode because the Safe Mode DIP switch is in the ON position Refer to the Configuring DIP Switches section for informatio...

Страница 22: ...he network settings and restart the NI 9792 for the LabVIEW run time engine to load Adding Removing and Replacing NI WSN 32xx Devices Use NI MAX to add and remove nodes to and from your NI Wireless Se...

Страница 23: ...ure 1 shows a typical NI Wireless Sensor Network The gateways and nodes work together to form a mesh network The gateway maintains a list of nodes by serial number that have been authorized for networ...

Страница 24: ...nfiguration R1 a router and R2 a router both communicate directly with the gateway Measurements taken by both devices can directly reach the gateway without having to hop through another node However...

Страница 25: ...r sending its own measurement data but also the R2 data This configuration is considered a worst case 1 hop system as R2 and R1 both have the possibility of meshing through a router that is connected...

Страница 26: ...ference such as buildings Another advantage of the mesh network is the ability to extend the distance of the end measurement from the wired Ethernet gateway By placing mesh routers throughout the spac...

Страница 27: ...m theoretical throughput of 250 kbps This correlates to a typical maximum rate of 1 sample per second per node Measurements taken with NI WSN 32xx nodes are single point acquisition NI WSN 32xx device...

Страница 28: ...cations Figure 18 Network Containing Distance Example 1 In this case all nodes have properly meshed and all nodes can communicate with the gateway However this network could potentially strand end nod...

Страница 29: ...ommunicate with R2 This prevents them from possibly joining R1 2 Add an additional router that is in range of the single end node This introduces the possibility of creating additional hops in the net...

Страница 30: ...net port 1 10 Mbps 100 Mbps auto negotiated Ethernet port 2 10 Mbps 100 Mbps auto negotiated Maximum cabling distance 100 m segment RS 232 DTE Serial Port Baud rate 300 230 400 bps Data bits 5 6 7 8 S...

Страница 31: ...mmended power supply 15 W secondary 35 VDC max Power consumption 9 5 W Maximum power consumption 15 W Voltage requirement On powerup 9 to 35 V After powerup 6 to 35 V Note For EMC compliance operate t...

Страница 32: ...signal levels special equipment limited energy parts of equipment circuits powered by regulated low voltage sources and electronics Caution Do not connect the system to signals or use for measurements...

Страница 33: ...ial Requirements of the R TTE Directive of the European Union 1999 5 EC This equipment meets the following conformance standards EN 301489 01 EN300 328 EN301 489 17 EN60950 Europe Restrictions for Use...

Страница 34: ...ssione ministeriale anche per l uso interno Verificare con i rivenditori la procedura da seguire Nederland License required for outdoor installations Check with reseller for procedure to follow Licent...

Страница 35: ...re relevante bepalingen van richtlijn 1999 5 EG Malti Maltese Hawnhekk National Instruments jiddikjara li dan NI WSN 9792 jikkonforma mal htigijiet essenzjali u ma provvedimenti ohrajn relevanti li he...

Страница 36: ...0 Hz Environmental Operating temperature IEC 60068 2 1 and IEC 60068 2 2 40 to 70 C Storage temperature IEC 60068 2 1 and IEC 60068 2 2 40 to 85 C Ingress protection IP 40 Operating humidity IEC 60068...

Страница 37: ...ocess or contact an authorized National Instruments service representative For more information about compliance with the EU Battery Directive 2006 66 EC about Batteries and Accumulators and Waste Bat...

Страница 38: ...hone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your lo...

Страница 39: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: