NI 9263 Calibration Procedure

Documentation

Consult the following documents for information about the NI 9263, NI-DAQmx, and your 
application software. All documents are available on 

ni.com

 and help files install with the 

software.

NI cDAQ-9174/9178 USB Chassis Quick Start

NI-DAQmx installation and hardware setup

NI 9263 Operating Instructions and Specifications

NI 9263 specific information, specifications, and calibration interval

NI-DAQmx Readme

Operating system and application software support in NI-DAQmx

LabVIEW Help

LabVIEW programming concepts and reference information about NI-DAQmx 
VIs and functions

NI-DAQmx C Reference Help

Reference information for NI-DAQmx C functions and NI-DAQmx C properties

NI-DAQmx .NET Help Support for Visual Studio

Reference information for NI-DAQmx .NET methods and NI-DAQmx .NET 
properties, key concepts, and a C enum to .NET enum mapping table

Содержание NI 9263

Страница 1: ...Initial Setup 3 Verification 4 Accuracy Verification 4 Adjustment 6 Accuracy Adjustment 6 EEPROM Update 6 Reverification 7 Accuracy Under Calibration Conditions 7 Worldwide Support and Services 8 Sof...

Страница 2: ...ctions and Specifications NI 9263 specific information specifications and calibration interval NI DAQmx Readme Operating system and application software support in NI DAQmx LabVIEW Help LabVIEW progra...

Страница 3: ...NI 9263 board temperature will be greater than the ambient temperature Keep relative humidity below 80 Allow a warm up time of at least 10 minutes to ensure that the NI 9263 measurement circuitry is...

Страница 4: ...Accuracy Verification Connections 3 Set the DMM to read DC voltage in the minimum range required to cover the NI 9263 output range of 10 V 4 Acquire a sample a Create and configure an AO voltage chann...

Страница 5: ...le was purchased before 2007 then use the Revision D limits Note Test limits in Table 4 are derived using the values in Table 7 Table 4 NI 9263 Revision D Test Limits Range V Test Point 1 Year Limits...

Страница 6: ...C value obtained from the array of recommended calibration voltages f Wait the appropriate amount of time for the DMM measurement to settle g Read the NI 9263 output voltage measurement from the DMM h...

Страница 7: ...e device to NI Accuracy Under Calibration Conditions The values in the following table are based on calibrated scaling coefficients which are stored in the onboard EEPROM The following accuracy table...

Страница 8: ...ur complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Ap...

Отзывы: