National Instruments NI-9232 Скачать руководство пользователя страница 8

Note

 Refer to the NI-9232 Specifications on 

ni.com/manuals

 for

complete specifications.

Connecting the NI-9232

The NI-9232 provides connections to three simultaneously sampled analog input

channels.

Figure 2. NI-9232 Pinout

AI0+

AI0–

AI1+

AI1–

AI2+

AI2–

0

1

0

1

0

1

AI0–
AI0+

AI1–
AI1+

AI2–
AI2+

Note

 You must use 2-wire ferrules to create a secure connection when

connecting more than one wire to a single terminal on the NI-9232 with

screw terminal.

Each channel has a terminal to which you can connect a signal source. The AI+

terminal of the connector provides the DC excitation, when enabled, and the

positive input signal connection. The AI- terminal provides the excitation return

path and the signal ground reference.

Signal

Description

AI+

Positive analog input signal connection

AI-

Negative analog input signal connection

Table 1. Signal Descriptions

Connecting Signal Sources

You can connect ground-referenced or floating signal sources to the NI-9232.

ni.com

8

NI-9232 Getting Started

Содержание NI-9232

Страница 1: ...NI 9232 Getting Started 2022 07 06...

Страница 2: ...lity Guidelines 5 Cable Requirements for EMC Compliance 6 Special Conditions for Marine Applications 7 Preparing the Environment 7 Connecting the NI 9232 8 Connecting Signal Sources 8 Wiring for High...

Страница 3: ...documentation d utilisation L utilisation du produit de toute autre fa on que celle sp cifi e risque de l endommager et de compromettre la protection de s curit int gr e Safety Voltages Connect only v...

Страница 4: ...ed hazardous classified location having a tool secured cover door where a minimum protection of at least IP54 is provided Caution For Division 2 and Zone 2 applications connected signals must be withi...

Страница 5: ...e reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in industrial locations Howev...

Страница 6: ...duct installation instructions Refer to the NI 9232 product page on ni com for purchasing information about clamp on ferrite beads Notice To ensure the specified EMC performance the length of all I O...

Страница 7: ...he EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power and input output ports In addition take precautions when designing selecting...

Страница 8: ...single terminal on the NI 9232 with screw terminal Each channel has a terminal to which you can connect a signal source The AI terminal of the connector provides the DC excitation when enabled and the...

Страница 9: ...ource Integrated Electronic Piezoelectric IEPE Sensors The NI 9232 provides an IEPE excitation current for each channel to measure the IEPE sensors Typical IEPE sensors have a case that is electricall...

Страница 10: ...earn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that...

Отзывы: