background image

© 2006–2013 National Instruments. All rights reserved. 

372026B-01

Jan13

CVI, LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National 
Instruments Corporation. Refer to the 

Trademark Information 

at 

ni.com/trademarks

 for other National Instruments trademarks. The mark 

LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States 
and other countries. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents 
covering National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on 

your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements 

(EULAs) and third-party legal notices in the NI-DAQmx Readme. Refer to the 

Export Compliance Information 

at 

ni.com/legal/

export-compliance

 for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other 

import/export data.

Where to Go for Support

The National Instruments Web site is your complete resource for technical support. At 

ni.com/support

 you have access to everything from troubleshooting and application 

development self-help resources to email and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world to 
help address your support needs. For telephone support in the United States, create your service 
request at 

ni.com/support

 and follow the calling instructions or dial 512 795 8248. For 

telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access the branch office Web sites, which provide up-to-date contact 

information, support phone numbers, email addresses, and current events.

Содержание NI 9215

Страница 1: ...irements 2 Test Equipment 3 Test Conditions 3 Initial Setup 3 Verification 4 Accuracy Verification 4 Adjustment 6 Accuracy Adjustment 6 EEPROM Update 7 Re Verification 7 Accuracy Under Calibration Con...

Страница 2: ...and Specifications NI 9215 specific information specifications and calibration interval NI DAQmx Readme Operating system and application software support in NI DAQmx LabVIEW Help LabVIEW programming...

Страница 3: ...thermal offsets Maintain an ambient temperature of 23 C 5 C The NI 9215 temperature will be greater than the ambient temperature Keep relative humidity below 80 Allow a warm up time of at least 10 min...

Страница 4: ...ion Complete the following procedure to determine the As Found status of the NI 9215 1 Set the calibrator to Standby mode STBY 2 Connect the NI 9215 to the calibrator Refer to Figure 1 for a connectio...

Страница 5: ...l according to Table 2 b Configure the AI voltage channel timing according to Table 3 c Start the task d Read samples from the NI 9215 e Average the samples for each channel f Clear the task 1 Connect...

Страница 6: ...ust the NI 9215 a Initialize a calibration session on the NI 9215 The default password is NI b Input the external temperature in degrees Celsius c Call the NI 9215 get C Series adjustment points funct...

Страница 7: ...n Repeat the Verification section to determine the As Left status of the device Note If any test fails Re Verification after performing an adjustment verify that you have met the Test Conditions befor...

Страница 8: ...s in the NI DAQmx Readme Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes E...