Capacitance

0.2 µF maximum

Special Conditions for Hazardous Locations Use in Europe and

Internationally

The NI 9213 has been evaluated as Ex nA IIC T4 Gc equipment under

DEMKO 07ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI 9213 is marked

 II 3G and is suitable for use in Zone 2 hazardous locations, in ambient

temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9213 in Gas Group IIC

hazardous locations, you must use the device in an NI chassis that has been

evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.

Caution

 Transient protection shall be provided that is set at a level not

exceeding 140% of the peak rated voltage value of 85 V at the supply

terminals to the equipment.

Caution

 The system shall only be used in an area of not more than

Pollution Degree 2, as defined in IEC/EN 60664-1.

Caution

 The system shall be mounted in an ATEX/IECEx-certified

enclosure with a minimum ingress protection rating of at least IP54 as

defined in IEC/EN 60079-15.

Caution

 The enclosure must have a door or cover accessible only by the

use of a tool.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits

for electromagnetic compatibility (EMC) stated in the product specifications. These

requirements and limits provide reasonable protection against harmful interference

when the product is operated in the intended operational electromagnetic

environment.

ni.com

6

NI-9213 Getting Started

Содержание NI 9213

Страница 1: ...NI 9213 Getting Started 2022 07 06...

Страница 2: ...lectromagnetic Compatibility Guidelines 6 Special Conditions for Marine Applications 7 Preparing the Environment 7 NI 9213 Pinout 8 Connecting a Thermocouple 8 Connecting to a Spring Terminal Connecto...

Страница 3: ...and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documentation Using the product in a manner not specified can damage the product and c...

Страница 4: ...voltage wiring is performed only by qualified personnel adhering to local electrical standards Attention S assurer que le c blage tension dangereuse est effectu par du personnel qualifi respectant le...

Страница 5: ...the NI 9213 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been swi...

Страница 6: ...peak rated voltage value of 85 V at the supply terminals to the equipment Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC EN 60664 1 Caution The...

Страница 7: ...products are approved for marine shipboard applications To verify marine approval certification for a product visit ni com product certifications search by model number and click the appropriate link...

Страница 8: ...17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 NC TC0 TC2 TC4 TC6 TC8 TC10 TC12 TC14 COM TC1 TC3 TC5 TC7 TC9 TC11 TC13 TC15 TC0 NC TC1 TC3 TC5 TC7 TC9 TC11 TC13 TC15 TC2 TC4 TC6 TC8 TC10...

Страница 9: ...ing steps to connect wires to the spring terminal connector 1 2 3 1 Insert the screwdriver into a spring clamp activation slot to open the corresponding connector terminal 2 Press a wire into the open...

Страница 10: ...across the terminals Keep the ambient temperature as stable as possible Make sure the NI 9213 terminals are facing forward or upward Keep the NI 9213 in a stable and consistent orientation Allow the...

Страница 11: ...learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures th...

Отзывы: