Tip

 You can also use the Ethernet port to connect directly to the host

computer or network. Refer to the user manual on 

ni.com/manuals

 for

more information about Ethernet connections.

Related information

Installing Software on the Host Computer

Configuring the System in Measurement & Automation

Explorer (MAX)

Complete the following steps to find the system in MAX.

1. Launch MAX on the host computer.
2. Expand 

Remote Systems

 in the configuration tree and locate your system.

3. Select your target.

Tip

 MAX lists the system under the model number followed by the

serial number, such as NI-cRIO-9149-1856AAA.

Setting a System Password

Complete the following steps to set a system password.

Note

 The default username for the NI 9149 is admin. There is no default

password for the NI 9149, so you must leave the password field blank when

logging in until you set a system password.

1. Right-click your system and select 

Web Configuration

.

The NI Web-Based Configuration and Monitoring utility opens in your default

browser and is where you set the password. If you have not installed Microsoft

Silverlight, NI Web-based Configuration & Monitoring prompts you to do so.

2. Enter a unique name for your system in the 

Hostname

 field.

ni.com

12

NI-9149 Getting Started

Содержание NI 9149

Страница 1: ...NI 9149 Getting Started 2022 07 06...

Страница 2: ...ies Modules 7 Removing C Series Modules 8 Connecting the NI 9149 8 Connecting the NI 9149 to Ground 8 Connecting the NI 9149 to Power 9 Connecting the NI 9149 to the Host Computer 11 Configuring the S...

Страница 3: ...mise the built in safety protection Return damaged models to NI for repair Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur L utilisation...

Страница 4: ...witched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impa...

Страница 5: ...ated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic env...

Страница 6: ...ent probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure that the environment in which you are using the NI 9149 meets the following specifications...

Страница 7: ...included in the NI 9149 kit Installing Software on the Host Computer Before using the NI 9149 you must install the following application software and device drivers on the host computer in this order...

Страница 8: ...hes lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on the C Series module before you remove a module from the NI 9149 If the system is in a nonhazard...

Страница 9: ...module with a plastic connector you must attach the cable shield to the chassis grounding terminal using 2 1 mm2 14 AWG or larger wire Attach a ring lug to the wire and attach the wire to the chassis...

Страница 10: ...PS 15 Industrial Power Supply 24 V DC 5 A 100 V AC to 120 V AC 200 V AC to 240 V AC input 781093 01 Table 2 NI Power Supplies What to Do Complete the following steps to connect a power supply to the...

Страница 11: ...wice every few seconds Related reference STATUS LED Indicators Connecting the NI 9149 to the Host Computer Complete the following steps to connect the NI 9149 to the host computer using the USB device...

Страница 12: ...the model number followed by the serial number such as NI cRIO 9149 1856AAA Setting a System Password Complete the following steps to set a system password Note The default username for the NI 9149 i...

Страница 13: ...following steps to install software on the NI 9149 1 In MAX expand your system under Remote Systems 2 Right click Software 3 Select Add Remove Software to launch the LabVIEW Real Time Software Wizard...

Страница 14: ...computer The USB driver creates a virtual network interface card and assigns an IP address to the NI 9149 in the format of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Ne...

Страница 15: ...ry few seconds 2 Set a new DHCP connection by holding the RESET button down for 5 seconds The STATUS LED repeats the same behavior from Step 1 If the NI 9149 fails to set a new DHCP address it assigns...

Страница 16: ...LED Indicators The following table describes the STATUS LED indicators LED Pattern Indication Blinks twice and pauses The NI 9149 is in safe mode Software is not installed which is the factory default...

Страница 17: ...Where to Go Next APPLICATION SUPPORT NI Community ni com community NI CompactRIO Developer s Guide ni com compactriodevguide Software Support ni com info swsupport Support ni com support SOFTWARE Comp...

Страница 18: ...com register to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI NI corporate headquarters is located at...

Отзывы: