background image

Note

 The C terminals are internally connected to each other.

4. Tighten the terminal screws on the power connector to 0.20 N · m to 0.25 N · m

(1.8 lb · in. to 2.2 lb · in.) of torque.

5. Install the power connector on the front panel of the NI 9149.
6. Tighten the power connector screw flanges to 0.20 N · m to 0.25 N · m

(1.8 lb · in. to 2.2 lb · in.) of torque.

7. Power on the power supply.

Powering On the NI 9149

When you power on the NI 9149 for the first time, the device boots into safe mode.

The POWER LED illuminates, the STATUS LED illuminates briefly, and then the

STATUS LED blinks twice every few seconds.

Related reference

STATUS LED Indicators

Connecting the NI 9149 to the Host Computer

Complete the following steps to connect the NI 9149 to the host computer using the

USB device port.

1. Power on the host computer.
2. Connect the NI 9149 to the host computer using the USB A-to-B cable.

Caution

 NI requires the use of a locking USB cable (157788-01) to

meet the shock and vibration specifications. Refer to the

specifications on 

ni.com/manuals

 for shock and vibration

specifications.

The device driver software automatically detects the NI 9149. If the device

driver software does not detect the NI 9149, verify that you installed the

appropriate NI software in the correct order on the host computer.

© National Instruments

11

NI-9149 Getting Started

Содержание NI 9149

Страница 1: ...NI 9149 Getting Started 2022 07 06...

Страница 2: ...ies Modules 7 Removing C Series Modules 8 Connecting the NI 9149 8 Connecting the NI 9149 to Ground 8 Connecting the NI 9149 to Power 9 Connecting the NI 9149 to the Host Computer 11 Configuring the S...

Страница 3: ...mise the built in safety protection Return damaged models to NI for repair Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur L utilisation...

Страница 4: ...witched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impa...

Страница 5: ...ated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic env...

Страница 6: ...ent probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure that the environment in which you are using the NI 9149 meets the following specifications...

Страница 7: ...included in the NI 9149 kit Installing Software on the Host Computer Before using the NI 9149 you must install the following application software and device drivers on the host computer in this order...

Страница 8: ...hes lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on the C Series module before you remove a module from the NI 9149 If the system is in a nonhazard...

Страница 9: ...module with a plastic connector you must attach the cable shield to the chassis grounding terminal using 2 1 mm2 14 AWG or larger wire Attach a ring lug to the wire and attach the wire to the chassis...

Страница 10: ...PS 15 Industrial Power Supply 24 V DC 5 A 100 V AC to 120 V AC 200 V AC to 240 V AC input 781093 01 Table 2 NI Power Supplies What to Do Complete the following steps to connect a power supply to the...

Страница 11: ...wice every few seconds Related reference STATUS LED Indicators Connecting the NI 9149 to the Host Computer Complete the following steps to connect the NI 9149 to the host computer using the USB device...

Страница 12: ...the model number followed by the serial number such as NI cRIO 9149 1856AAA Setting a System Password Complete the following steps to set a system password Note The default username for the NI 9149 i...

Страница 13: ...following steps to install software on the NI 9149 1 In MAX expand your system under Remote Systems 2 Right click Software 3 Select Add Remove Software to launch the LabVIEW Real Time Software Wizard...

Страница 14: ...computer The USB driver creates a virtual network interface card and assigns an IP address to the NI 9149 in the format of 172 22 11 x 2 In MAX expand your system under Remote Systems 3 Select the Ne...

Страница 15: ...ry few seconds 2 Set a new DHCP connection by holding the RESET button down for 5 seconds The STATUS LED repeats the same behavior from Step 1 If the NI 9149 fails to set a new DHCP address it assigns...

Страница 16: ...LED Indicators The following table describes the STATUS LED indicators LED Pattern Indication Blinks twice and pauses The NI 9149 is in safe mode Software is not installed which is the factory default...

Страница 17: ...Where to Go Next APPLICATION SUPPORT NI Community ni com community NI CompactRIO Developer s Guide ni com compactriodevguide Software Support ni com info swsupport Support ni com support SOFTWARE Comp...

Страница 18: ...com register to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI NI corporate headquarters is located at...

Отзывы: