7. The recommended software set is preselected from the list of software add-ons. Check
any additional software add-ons you want. The System State Publisher, for example,
makes monitoring system performance simple.
Note
You can use the LabVIEW Real-Time Software Wizard to install more
software add-ons later. The FlexRIO 15.0 Recommended Software Set is
enough to get started.
8. Click
Next
.
9. Review the summary of software to install. Click
Next
to begin the update.
10. Wait for the installation to finish, and then click
Finish
.
Adding the NI-7932R to a LabVIEW Project
1. Launch LabVIEW. The LabVIEW
Getting Started
window appears.
2. Click
Create Project
or open an existing project.
3. Right-click the project root in the
Project Explorer
window and select
New
»
Targets
and Devices
from the shortcut menu to display the
Add Targets and Devices
dialog box.
a) If the hardware is connected to the host, select
Existing target or device
. Select the
NI-7932R under
Real-Time FlexRIO
and click
OK
.
b) If the hardware is not connected to the host, select
New target or device
. Select the
NI-7932R under
Real-Time FlexRIO
and click
OK
.
4. Right-click the target and select
New
»
FPGA Target
.
The FPGA target appears in the project under the Real-Time target.
Adding a FlexRIO Adapter Module to the Target
Skip this section if you are not using an adapter module.
1. Expand the FPGA target by clicking the
+
button, then right-click
IO Module
and select
Properties
.
2. Select the
General
category and check the
Enable IO Module
box.
3. Select your I/O module from the
IO Modules
list, and select the CLIP you want to use
from the
Component Level IP
box.
4. Click
OK
.
NI-7932R Getting Started Guide
|