Programming Devices in Software

National Instruments measurement devices are packaged with NI-DAQ 
driver software, an extensive library of functions and VIs you can call from 
your application software, such as LabVIEW or LabWindows

/CVI

, to 

program all the features of your NI measurement devices. Driver software 
has an application programming interface (API), which is a library of VIs, 
functions, classes, attributes, and properties for creating applications for 
your device.

NI-DAQ 8.

x

 includes two NI-DAQ drivers, Traditional NI-DAQ (Legacy) 

and NI-DAQmx. Each driver has its own API, hardware configuration, and 
software configuration. Refer to the 

DAQ Getting Started Guide

 for more 

information about the two drivers.

Traditional NI-DAQ (Legacy) and NI-DAQmx each include a collection of 
programming examples to help you get started developing an application. 
You can modify example code and save it in an application. You can use 
examples to develop a new application or add example code to an existing 
application.

To locate LabVIEW and LabWindows/CVI examples, open the National 
Instruments Example Finder:

In LabVIEW, select 

Help»Find Examples

.

In LabWindows/CVI, select 

Help»NI Example Finder

.

Measurement Studio, Visual Basic, and ANSI C examples are in the 
following directories:

NI-DAQmx examples for Measurement Studio-supported languages 
are in the following directories:

MeasurementStudio\VCNET\Examples\NIDaq

MeasurementStudio\DotNET\Examples\NIDaq

Traditional NI-DAQ (Legacy) examples for Visual Basic are in the 
following two directories:

NI-DAQ\Examples\Visual Basic with Measurement 

Studio

 directory contains a link to the ActiveX control examples 

for use with Measurement Studio

NI-DAQ\Examples\VBasic

 directory contains the examples not 

associated with Measurement Studio

NI-DAQmx examples for ANSI C are in the 

NI-DAQ\Examples\

DAQmx ANSI C Dev

 directory

Traditional NI-DAQ (Legacy) examples for ANSI C are in the 

NI-DAQ\Examples\VisualC

 directory

For additional examples, refer to 

zone.ni.com

.

Содержание NI 6509

Страница 1: ...are 3 Functional Overview 4 Safety Information 4 Related Documentation 6 Features 7 Digital Filtering 7 Digital Filtering Example 8 Programmable Power Up States 8 Change Detection 9 Change Detection E...

Страница 2: ...09 device and the software are installed the DAQ device appears under the Devices and Interfaces branch of the MAX configuration tree If the DAQ device does not appear in MAX use the following trouble...

Страница 3: ...modify example code and save it in an application You can use examples to develop a new application or add example code to an existing application To locate LabVIEW and LabWindows CVI examples open th...

Страница 4: ...dify the DIO device except as described in this help file Use the DIO device only with the chassis modules accessories and cables specified in the installation instructions You must have all covers an...

Страница 5: ...ody and the connector block signal when hot swapping modules Remove power from signal lines before connecting them to or disconnecting them from the DIO device Operate the DIO device at or below the m...

Страница 6: ...is for measurements performed at the primary electrical supply installation 1 000 V Examples include electricity meters and measurements on primary overcurrent protection devices and on ripple contro...

Страница 7: ...eed to be passed and blocked You can enable filtering on as many input lines as necessary for your application All filtered lines share the same timing interval which ranges from 400 ns to 200 ms Inte...

Страница 8: ...nsition The same filtering applies to falling 1 to 0 transitions Programmable Power Up States At power up the output drives on the NI 6509 are disabled All lines are user configurable for high impedan...

Страница 9: ...the changes occurs but it does not report which line changed or if the line was rising or falling After a change you can read the input lines to determine the current line states The maximum rate of c...

Страница 10: ...Timer The watchdog timer is a software configurable feature used to set critical outputs to safe states in the event of a software failure a system crash or any other loss of communication between the...

Страница 11: ...digital I O cable with the SCB 100 connector block or use the R1005050 ribbon cable with the CB 50 or CB 50LP connector block Caution Do not make connections to the digital I O that exceed the maximu...

Страница 12: ...4 P2 4 P5 5 P2 5 P5 6 P2 6 P5 7 5 V P9 0 P6 0 P9 1 P6 1 P9 2 P6 2 P9 3 P6 3 P9 4 P6 4 P9 5 P6 5 P9 6 P6 6 P9 7 P6 7 P10 0 P7 0 P10 1 P7 1 P10 2 P7 2 P10 3 P7 3 P10 4 P7 4 P10 5 P7 5 P10 6 P7 6 P10 7 P...

Страница 13: ...P2 4 P2 5 P2 6 P2 7 GND P3 1 P3 2 P3 4 P3 5 P3 6 P3 7 P3 0 P3 3 P4 0 P4 1 P4 2 P4 3 P4 4 P4 5 P4 6 P4 7 P5 0 P5 1 P5 2 P5 3 P5 4 P5 5 P5 6 P5 7 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31...

Страница 14: ...35 37 39 41 43 45 47 P0 7 0 Bi directional data lines for port 0 P0 7 P0 0 34 36 38 40 42 44 46 48 P3 7 0 Bi directional data lines for port 3 P3 7 P3 0 49 99 5 V supply 5 volts provides 5 V power sou...

Страница 15: ...Signal Connections The maximum input logic high and output logic high voltages assume a Vcc supply voltage of 5 V The absolute maximum voltage rating is 0 5 to 5 5 V with respect to GND Refer to the...

Страница 16: ...in the inductive load These flyback voltages can damage the outputs and or the power supply To limit these flyback voltages at the inductive load install a flyback diode across the inductive load For...

Страница 17: ...ay less than 24 mA driving a relay greater than 24 mA and driving solid state relays Driving a Relay 24 mA Figures 7 and 8 show examples of connecting the NI 6509 to a relay that does not require more...

Страница 18: ...urrent These examples use an additional transistor circuit Figure 9 NI 6509 Sinking Connection Example 24 mA Figure 10 NI 6509 Sourcing Connection Example 24 mA Driving SSRs Figure 11 shows an example...

Страница 19: ...load current 250 mA on 5 VDC With a load use the following equation to determine the power consumption on a 5 V rail In the equation j is the number of channels you are using to source current Power...

Страница 20: ...ND Output Signals Vcc 5 V The total current sinking sourcing from one port cannot exceed 100 mA 5V power available at I O connector pins 49 and 99 4 65 to 5 25 V Note The I O connector power has a fus...

Страница 21: ...evice is intended for indoor use only Operating Environment Ambient temperature range 0 to 55 C tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing...

Страница 22: ...Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA...

Страница 23: ...this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Environmental Management National Instruments is committed to...

Отзывы: