Appendix A
Device-Specific Information
©
National Instruments Corporation
A-27
SCXI Accessories
SCXI is a programmable signal conditioning system designed for
measurement and automation applications. To connect your M Series
device to an SCXI chassis, use the SCXI-1349 adapter and an
SHC68-68-EPM cable.
Use Connector 0 of your M Series device to control SCXI. NI-DAQ 7.4
and later supports SCXI in parallel mode on Connector 1.
Note
When using Connector 1 in parallel mode with SCXI modules that support track and
hold, you must programmatically disable track and hold.
You also can use an M Series device to control the SCXI section of a
PXI/SCXI combination chassis, such as the PXI-1010 or PXI-1011. The
M Series device in the rightmost PXI slot controls the SCXI devices.
No cables or adapters are necessary.
Refer to the
SCXI Advisor
, available by going to
ni.com/info
and
entering the info code
rdscad
, for more information.
SCC Accessories
SCC provides portable, modular signal conditioning to your DAQ system.
To connect your M Series device to an SCC module carrier, such as the
SC-2345, SC-2350, or SCC-68, use an SHC68-68-EPM shielded cable.
Use Connector 0 of your M Series device to control an SCC module carrier.
SCC carriers can be used with Connector 1 with NI-DAQ 7.4 and later.
Refer to the
SCC Advisor
, available by going to
ni.com/info
and
entering the info code
rdscav
, for more information.
BNC Accessories
You can use the SHC68-68-EPM shielded cable, to connect your DAQ
device to BNC accessories, such as the following:
•
BNC-2110
—Provides BNC connectivity to all analog signals, some
digital signals, and spring terminals for other digital signals
•
BNC-2111
—Provides BNC connectivity to 16 single-ended analog
input signals, two analog output signals, five DIO/PFI signals, and the
external reference voltage for analog output