Note

If the device does not pass the self-test, repeat the instructions in section 

5. 

Installing the Hardware

. If the device still does not pass, visit NI Technical Support 

at 

ni.com/support

.

6.

Run the test panels on the device to verify the signal.
a.

Connect a signal to the digitizer and select the appropriate device parameters for this 
signal such as range, input limits, sample rate, and sample mode.

b.

Access the test panel.

Right-click the device and select 

Test Panels

(Traditional NI-DAQ [Legacy] Devices)

 Click 

Run Test Panels

 in the 

Configure window.

Note

All NI digitizers have self-calibration capabilities. You can access this feature 

programmatically with NI-SCOPE and your ADE, or you can use either the 
NI-SCOPE Soft Front Panel (SFP) or MAX. Traditional NI-DAQ (Legacy) devices 
cannot be self-calibrated using MAX.

7.

Exit MAX when you have finished configuring and testing the digitizer.

7. Programming the Device

You can acquire data interactively using the NI-SCOPE Soft Front Panel or programmatically 
using the NI-SCOPE instrument driver in your application. You can also run the NI-SCOPE 
examples to demonstrate the functionality of the digitizer.

Acquiring Data Interactively

Launch the NI-SCOPE SFP from 

Start»All Programs»National Instruments»NI-SCOPE»

SCOPE Soft Front Panel

(Windows 8) 

Click 

NI Launcher

 and select 

NI-SCOPE»SCOPE 

Soft Front Panel 

in the window that appears. The NI-SCOPE SFP provides context-sensitive 

help for its controls. 

Acquiring Data Programmatically

You can use NI-SCOPE to begin programming the digitizer in your ADE. For detailed 
instructions about how to acquire data in a specific ADE, refer to the 

Getting Started with 

NI-SCOPE 

section of the 

NI High-Speed Digitizers Help

 located at 

Start»All Programs»

National Instruments»NI-SCOPE»Documentation»NI High-Speed Digitizers Help. 

(Windows 8) 

Click 

NI Launcher

 and select 

NI-SCOPE»Documentation»NI High-Speed 

Digitizers Help

 in the window that appears.

Tip

You can modify an NI-SCOPE C example to create an application with 

Microsoft Visual C/C++, and all required include and library files are automatically 
added to the project. Refer to the 

Creating an Application with Microsoft Visual C 

and C++

 topic of the 

NI High-Speed Digitizers Help

 if you prefer to manually add 

all required include and library files to the project.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание NI 5105

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...ocument included with your device To access these documents select Start All Programs National Instruments NI SCOPE Documentation Windows 8 Click NI Launcher and select NI SCOPE Documentation in the w...

Страница 3: ...31 Front Panel ACCESS LED on PXI PXI Express Module is Off when PXI PXI Express Chassis is On 31 Back Panel LED on USB Module is Off when Device is Plugged In 31 Device Does Not Appear in MAX 32 Devic...

Страница 4: ...you are touching a grounded metal object Handle the digitizer carefully to avoid touching any exposed pins or electronic circuitry Remove the digitizer from the package remove the packing foam and ru...

Страница 5: ...on for PCI Devices you must use a RTSI cable to connect the PCI DeviceS For more information refer to NI High Speed Digitizers Help Programming Reference NI TClk Synchronization Help 4 Installing the...

Страница 6: ...imums Keep the module free of dust by cleaning with compressed air only Do not clean the device with any solvents or liquids You can install PXI modules in any PXI slot marked with a peripheral slot c...

Страница 7: ...h you can purchase at ni com 10 Plug in and power on the chassis Figure 1 PXI Module Installation Figure 2 PXI Express Module Installation NI PXIe 5185 5186 Modules Follow the installation instruction...

Страница 8: ...backplane in two adjacent PXI Express slots Figure 3 NI PXIe 5185 5186 Connector Figure 4 NI 5185 5186 Installation 1 PXI Express Connectors 2 NI PXIe 5186 Module 1 PXI Express Chassis 2 Ejector Hand...

Страница 9: ...subsequent boot cycle The module will begin the initialization procedure after the NI SCOPE driver has been loaded by the operating system PCI Devices To install a PCI device complete the following st...

Страница 10: ...um clocking is enabled in the PC BIOS For information about how to verify this setting refer to the PC user documentation Note For SMC based devices spread spectrum clocking varies the clock signal to...

Страница 11: ...our USB cable size as shown in Figure 7 Zip Tie Method Thread a zip tie through the zip tie bar on the underside of the USB device and tighten around the USB cable as shown in Figure 7 Figure 7 USB Ca...

Страница 12: ...te Do not apply the rubber feet if you are panel mounting the NI USB 5132 5133 or stacking it on top of another NI USB 5132 5133 device Figure 8 Applying Rubber Feet to the USB 513x DIN Rail Mounting...

Страница 13: ...in the KnowledgeBase document USB 4065 5132 5133 6509 Panel Mounting Template Go to ni com info and enter the Info Code rd3233 to locate the KnowledgeBase document 2 Using the template mark the botto...

Страница 14: ...options which may vary depending on the devices and software installed on your system Begin a Measurement with This Device Using NI SignalExpress opens SignalExpress Use This Device Interactively laun...

Страница 15: ...the Hardware For more information about using MAX refer to the help files available within MAX Note Windows 8 64 bit Windows 7 64 bit and Windows Vista 64 bit do not support Traditional NI DAQ Legacy...

Страница 16: ...You can also run the NI SCOPE examples to demonstrate the functionality of the digitizer Acquiring Data Interactively Launch the NI SCOPE SFP from Start All Programs National Instruments NI SCOPE SCO...

Страница 17: ...name control or parameter This string varies if the digitizer is a Traditional NI DAQ device For more information about device names refer to any of the following resources Section 6 Configuring and...

Страница 18: ...ed Devices and USB Devices This appendix describes digitizer front panels and signal connections for SMC based devices and USB devices NI 5105 NI 5114 NI 5122 NI 5124 NI 5132 NI 5133 NI 5142 NI 5152 N...

Страница 19: ...I 5105 Front Panel Signal Connections Connector Description Function CH 0 CH 7 Standard SMB jack connector Analog input connection digitizes data and triggers acquisitions PFI 1 Standard SMB jack conn...

Страница 20: ...tion Function CH 0 CH 1 Standard BNC female connector Analog input connection digitizes data and triggers acquisitions TRIG Standard BNC female connector External analog trigger connection signals on...

Страница 21: ...TRIG connector cannot be digitized CLK IN Standard SMB jack connector NI 5122 5124 5142 Input for an external reference clock or sample clock to the digitizer NI 5922 Input for an external reference...

Страница 22: ...ed USB port 2 LED 3 Ground Table 4 NI 5132 5133 Front Panel Signal Connections Connector Description Function CH 0 CH 1 Standard BNC female connector Analog input connection digitizes data and trigger...

Страница 23: ...nnector Analog input connection digitizes data and triggers acquisitions TRIG Standard BNC female connector External analog trigger connection signals on the TRIG connector cannot be digitized PFI 0 S...

Страница 24: ...nalog input connection digitizes data and triggers acquisitions TRIG Standard BNC connector External analog trigger connection signals on the TRIG connector cannot be digitized CLK IN Standard SMB jac...

Страница 25: ...SMB jack Digital trigger in out PFI 1 Standard SMB jack Digital trigger in out probe compensation Table 6 NI 5160 5162 2 CH Front Panel Signal Connections Continued Connector Description Function 9SN...

Страница 26: ...sample clock in CLK OUT Standard SMB jack Reference clock out PFI 0 Standard SMB jack Digital trigger in out PFI 1 Standard SMB jack Digital trigger in out probe compensation 5 GHz 12 5 GS s 8 Bit Dig...

Страница 27: ...any letter and z is any number support both 50 and 1 M input impedance Table 8 NI 5185 5186 Front Panel Signal Connections Connector Description Function REF CLK Standard SMB jack connector Imports a...

Страница 28: ...nnection digitizes data and triggers acquisitions PFI 1 SMB jack connector Digital trigger connection Multipurpose PFI line for reference clock in sample clock in and digital trigger in out CLK IN SMA...

Страница 29: ...5621 NI 5620 5621 Front Panels Figure 22 shows the NI PXI 5620 5621 front panels Figure 22 NI 5620 5621 Front Panels NI PXI 5621 64 MS s Digitizer INPUT 50 20 dBm MAX 3 VDC MAX REF CLK IN PFI 1 50 20...

Страница 30: ...ifier front panel and the connections to the NI 5922 Table 10 NI 5620 5621 Front Panel Signal Connections Connector Description Function INPUT Standard SMA female connector Analog input connection dig...

Страница 31: ...l analog input signal for channel 0 CH 0 OUT Standard SMB jack connector Single ended analog output for channel 0 approximately CH0 CH0 4 CH 1 Standard BNC female connector Differential analog input s...

Страница 32: ...orming device resets and self tests in MAX refer to section 6 Configuring and Testing in MAX 8 If the ACCESS LED still fails to light contact NI Technical Support at ni com support Back Panel LED on U...

Страница 33: ...u receive an over temperature or thermal shutdown error and your device shuts down complete the following steps to re enable your device 1 Power off the computer or chassis that contains the device 2...

Страница 34: ...igh Speed Digitizers Help Programming Reference NI TClk Synchronization Help If you plan to share triggers and or clocks for the purpose of synchronizing SMC based devices you must identify or configu...

Страница 35: ...by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is...

Страница 36: ...txt file on your media or the National Instruments Patents Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file f...

Страница 37: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: