Table 5. Non-Spatial Data Measurements (Continued)
Measurement
Description
BeamPeakOBWPower
Absolute power, in dBm, of the occupied bandwidth at
beam peak.
BeamPeakOBWStartFrequency
Start frequency of the occupied bandwidth at beam peak.
BeamPeakOBWStopFrequency
Stop frequency of the occupied bandwidth at beam peak.
SEMAggregatedStatus
Aggregated SEM status.
SingleToneTRP
Total radiated power using a single tone waveform.
Table 6. Spatial Measurements
Measurement
Description
CHP
Channel power in dBm.
ACPLower
Lower offset channel power, in dBm.
ACPUpper
Upper offset channel power, in dBm.
EVM(RMS)
RMS of EVMs, in percent.
EVM(Peak)
Maximum of EVMs, in percent.
SEMMargin
Worst-case margin, in dB.
SEMStatus
Whether the power is within the standard defined limit.
SingleTone
Single tone waveform peak power, in dBm.
Note
Refer to the
for more information about specific
measurements.
OTA Measurement Interface
The OTA Measurement Interface (OTAMI) is the primary interface for your measurement
data. Use the OTAMI to store measurements, import and export measurement data, and post-
process your measurement results.
Note
OTAMI cannot be used to interact with the system components, positioner, or
DUT.
OTAMI Features
•
Calculates measurement results for the following measurements: TRP, Peak EIRP, Gain,
HPBW, FNBW, Pattern Cuts
•
Provides measurement data for results visualization