National Instruments ISM-7413 Скачать руководство пользователя страница 28

© 2016 National Instruments. All rights reserved. 

374808B-01

Jun16

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 

Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 

telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 

Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 

events.

RRRRRRRG

7 red, 1 green

Serial communication error

RRRRRRRGG

7 red, 2 green

Flash memory error

Table 2.  

Status LED Blink Code Definitions (Continued)

Blink sequence

Code

Error

Содержание ISM-7413

Страница 1: ...ISM 7413...

Страница 2: ...t 7 Option 1 Connect a Drive to Your LAN 9 Option 2 Connect a Device Directly to Your PC 10 Option 3 Use Two Network Interface Cards NICs 11 Connecting Input Signals 12 Connection Examples STEP DIR 13...

Страница 3: ...cable not included NI Stepper Configuration Utility available from ni com downloads Refer to Choosing a Power Supply for more information IN1 AIN GND 5V IN1 IN2 IN2 IN3 IN3 OUT4 OUT4 Power Conn 12 70...

Страница 4: ...se the surrounding air to be higher than 40 C Caution Never put the NI ISM 7413 where it can get wet or where metal or other electrically conductive particles can contact the circuitry Caution Always...

Страница 5: ...I ISM 7412 When you rapidly decelerate a load from a high speed much of the kinetic energy of that load transfers back to the power supply This transfer can trigger the overvoltage protection of a swi...

Страница 6: ...power supply current required by the motor at various voltages is shown in the following charts The supply current flowing into the motor may be less than the motor phase current because the motor am...

Страница 7: ...V Power Supply Speed RPS Torque N m 2 5 3 0 2 0 1 5 1 0 0 5 0 0 5 00 4 00 3 00 2 00 1 00 0 4 50 3 50 2 50 1 50 0 5 10 20 30 40 50 Torque Supply Current Supply Current No Load Speed RPS Torque N m 2 5...

Страница 8: ...ower supplies are better suited for applications with significant regeneration as they generally do not have overvoltage protection and have large capacitors for storing energy coming back from the dr...

Страница 9: ...tomatically assigned by the DHCP server may be dynamic or static depending on how the administrator has configured DHCP The DHCP setting is reserved for advanced users Your PC or any other equipment t...

Страница 10: ...witch settings 4 through E Another common subnet is 192 168 1 If your network uses addresses in this range the compatible default selections are 1 2 and 3 If your PC address is not in one of the above...

Страница 11: ...alog Dialog Box Normally Drive Discovery only detects one network interface card NIC and selects it automatically If you are using a laptop and have both wireless and wired network connections a secon...

Страница 12: ...s technique allows you to keep your PC connected to your LAN but keeps the device off the LAN preventing possible IP conflicts or excessive traffic 1 If you use a desktop PC and have a spare card slot...

Страница 13: ...will receive a small message bubble in the corner of your screen saying The network cable is unplugged Connecting Input Signals The NI ISM 7413 has three digital inputs and one analog input STEP High...

Страница 14: ...ure 11 Internal Circuit Diagram Connection Examples STEP DIR Figure 12 Connecting to Indexer with Sourcing Outputs RES STEP STEP DIR DIR EN EN OUT OUT AIN GND Signal Conditioning 5V 50 mA Limit ISM 74...

Страница 15: ...Configuration Utility the STEP DIR inputs are reconfigured to accept limit switch input The STEP input can be used with a forward limit CW switch while the DIR input can be used with a reverse limit...

Страница 16: ...ch or Relay Connecting the Enable signal as shown in Figures 17 and 18 causes the drive to disable when the proximity sensor activates Figure 17 Connecting an NPN Type Proximity Sensor to an Input Fig...

Страница 17: ...to automatically control a motor brake or signal fault conditions You can also use it to drive LEDs relays and the inputs of other electronic devices like PLCs The positive collector OUT and negative...

Страница 18: ...be set to one of two motion command modes Pulse and Direction mode accepts a signal such as that generated by an external indexer or motion controller With this mode the frequency of the pulses fed in...

Страница 19: ...ortant if the motor is not mounted to a surface that will help it conduct heat away or if you expect the ambient temperature to be high Step motors produce torque in direct proportion to current but t...

Страница 20: ...ts Load Inertia The NI ISM 7413 includes anti resonance and electronic damping features which greatly improve motor performance To perform optimally the drive must understand the electromechanical cha...

Страница 21: ...mooth motor acceleration and deceleration This is only a consideration when using a source other than ENET control Smaller step sizes result in smoother motion and more precise speed but also require...

Страница 22: ...Consider the maximum pulse rate when deciding whether you must increase the filter frequency EN Input You can configure the behavior of the EN input Common applications use EN as a relay to turn the...

Страница 23: ...ther than load There are certain combinations of speed and voltage at which you can continuously operate a motor without damage The drive electronics of the NI ISM 7413 also dissipate power The heat p...

Страница 24: ...One hour on and one hour off results in 100 duty because the motor will reach full and possibly excessive temperature during the first hour of use Note National Instruments tested the NI ISM 7413 in a...

Страница 25: ...413 Technical Specifications Amplifier Amplifier type Dual H bridge 4 quadrant Current control 4 state PWM 20 kHz Protection Over voltage under voltage over temperature motor wiring shorts Supply volt...

Страница 26: ...g or differential signals can be used Minimum on voltage 4 VDC Maximum voltage 30 VDC Maximum pulse frequency 3 MHz Minimum pulse width 250 ns Analog Input AIN is referenced to GND Range 0 to 5 VDC Re...

Страница 27: ...abled GG slow Flashing green slowly No alarm motor enabled GG rapid Flashing green quickly Q Program running RG 1 red 1 green Motor stall encoder equipped only RGG 1 red 2 green Move attempted drive d...

Страница 28: ...hts as set forth in FAR 52 227 14 DFAR 252 227 7014 and DFAR 252 227 7015 Worldwide Support and Services The National Instruments website is your complete resource for technical support At ni com supp...

Отзывы: