Attribute Name
Data
Type
Range
Unit
Description
TriggerSource
Enum
Input 0, Input
1, Input 2,
Input 3
(Windows
only), Fixed
Rate, Software
—
Determines the
source of the
selected trigger
UserLEDState
Enum
Off, Green,
Red, Orange
—
Gets/sets the value
of the User LED
UserOutputSelector
Enum
User Output 0,
User Output 1,
User Output 2
—
Selects which bit of
the User Output
register will be set
UserOutputValue
Bool
—
—
Gets/sets the status
of the selected user
output
UserOutputValueAll
U32
0 to 7
—
Gets/sets the value
of all bits in the
User Output
register
Width
U32
Model
dependent
Pixels Gets/sets the width
of the image.
Restoring the NI Linux Real-Time Operating
System
Complete the following steps to restore the NI Linux Real-Time operating system to its factory
default condition. These steps do not restore the BIOS settings to factory default. Use the
Load Optimal Defaults
option in the
Exit Menu
of the BIOS setup utility to restore the BIOS
settings.
Caution
Restoring the operating system erases the contents of the onboard storage.
Back up any files you want to keep before restoring the onboard storage.
1. Start the ISC-178x in safe mode.
2. Launch NI MAX on the development computer.
3. In the MAX configuration tree, expand
Remote Systems
.
4. Right-click the name of the ISC-178x you want to restore and select
Format Disk
.
5. Enter the username and password for the device. By default, the username is
admin
and
the password field is blank.
ISC-178x User Manual
|
© National Instruments
|
35