background image

Chapter 2

Configuration and Installation

©

 National Instruments Corporation

2-3

IMAQ PCI-1424 User Manual

Safety Information

Caution

The following paragraphs contain important safety information you 

must

 follow 

when installing and operating the device.

Do 

not 

operate the module in a manner not specified in this document. 

Misuse of the module can result in a hazard. You can compromise the safety 
protection built into the module if the module is damaged in any way. If the 
module is damaged, return it to National Instruments (NI) for repair.

Do 

not

 substitute parts or modify the module except as described in this 

document. Use the module only with the chassis, modules, accessories, and 
cables specified in the installation instructions. You must have all covers 
and filler panels installed during operation of the module.

Do 

not

 operate the module in an explosive atmosphere or where there may 

be flammable gases or fumes. If you must operate the module in such an 
environment, it must be in a suitably rated enclosure.

If you need to clean the module, use a soft, nonmetallic brush. Make sure 
that the module is completely dry and free from contaminants before 
returning it to service.

Operate the module only at or below Pollution Degree 2. Pollution is 
foreign matter in a solid, liquid, or gaseous state that can reduce dielectric 
strength or surface resistivity. The following is a description of pollution 
degrees:

Pollution Degree 1 means no pollution or only dry, nonconductive 
pollution occurs. The pollution has no influence.

Pollution Degree 2 means that only nonconductive pollution occurs in 
most cases. Occasionally, however, a temporary conductivity caused 
by condensation must be expected.

Pollution Degree 3 means that conductive pollution occurs, or dry, 
nonconductive pollution occurs that becomes conductive due to 
condensation.

You 

must

 insulate signal connections for the maximum voltage for which 

the module is rated. Do 

not

 exceed the maximum ratings for the module. 

Do not install wiring while the module is live with electrical signals. Do not 
remove or add connector blocks when power is connected to the system. 

Содержание IMAQ PCI-1424

Страница 1: ...IMAQ TM IMAQ PCI 1424 User Manual High Quality Digital Image Acquisition Device for PCI IMAQ PCI 1424 User Manual August 2004 371869C 01...

Страница 2: ...90000 Israel 972 0 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Malaysia 603 9131 0918 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47...

Страница 3: ...r surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form el...

Страница 4: ...t of Communications DOC Changes or modifications not expressly approved by NI could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission Thi...

Страница 5: ...enotes a warning advising you to take precautions to avoid electrical shock When symbol is marked on a product it denotes a component that may be hot Touching this component may result in bodily injur...

Страница 6: ...sion and Motion 1 4 Chapter 2 Configuration and Installation What You Need to Get Started 2 1 Optional Equipment 2 2 Unpacking 2 2 Safety Information 2 3 Installation 2 5 Chapter 3 Hardware Overview F...

Страница 7: ...ts IMAQ PCI 1424 User Manual viii ni com Chapter 4 Signal Connections I O Connector 4 1 Signal Description 4 3 Appendix A Specifications Appendix B Technical Support and Professional Services Glossary...

Страница 8: ...egister level Featuring a high speed data flow path the PCI 1424 is ideal for both industrial and scientific environments As a standalone device the PCI 1424 supports up to 32 bits of differential or...

Страница 9: ...PCI 1424 device NI IMAQ has an extensive library of functions you can call from your application programming environment such as routines for video configuration image acquisition continuous and sing...

Страница 10: ...of your applications if necessary Vision Builder AI is available for LabVIEW LabWindows CVI and Measurement Studio which includes support for Visual Basic Vision Development Module The Vision Develop...

Страница 11: ...sing LabVIEW you can add functionality to this generated VI Integration with DAQ Platforms that support NI IMAQ also support NI DAQ and a variety of National Instruments DAQ devices This allows integr...

Страница 12: ...device What You Need to Get Started To set up and use your PCI 1424 you will need the following PCI 1424 device NI IMAQ for Windows 2000 NT XP Optional software packages and documentation NI Vision Bu...

Страница 13: ...r specific information about these products refer to the National Instruments catalog visit ni com or call the office nearest you Unpacking The PCI 1424 device ships in an antistatic package to preven...

Страница 14: ...n environment it must be in a suitably rated enclosure If you need to clean the module use a soft nonmetallic brush Make sure that the module is completely dry and free from contaminants before return...

Страница 15: ...trical distribution system This category refers to local level electrical distribution such as that provided by a standard wall outlet for example 115 AC voltage for U S or 230 AC voltage for Europe E...

Страница 16: ...ice 3 Remove the computer cover Make sure there are no lit LEDs on the motherboard If any are lit wait until they go out before continuing installation 4 Touch the metal part of the power supply case...

Страница 17: ...CI 1424 device device and explains the operation of each functional unit making up the PCI 1424 Functional Overview The PCI 1424 features a flexible high speed data path optimized for the reception an...

Страница 18: ...ess power consumption longer cable lengths less noise and higher clock rates LUTs You can configure the PCI 1424 to use either four 8 bit or two 10 bit to 16 bit lookup tables LUTs to perform LUT oper...

Страница 19: ...in 64 MB and 128 MB densities The PCI 1424 can also use the onboard RAM as a first in first out FIFO buffer so that in some instances the PCI 1424 can capture images larger than the amount of RAM on...

Страница 20: ...rs The DMA controllers transfer data between the onboard SDRAM memory buffers and the PCI bus Each of these controllers supports scatter gather DMA which allows the DMA controller to reconfigure on th...

Страница 21: ...xel region selects the starting pixel and number of pixels to be acquired relative to the assertion edge of the horizontal or line enable signal from the camera The active line region selects the star...

Страница 22: ...o data inputs digital enable inputs camera control outputs RS 232 serial interface and the external trigger signals To access these connections you can build your own custom cable or use one of the op...

Страница 23: ...l Trigger1 EnableC External Trigger0 EnableB SIN RS 232 EnableB SOUT RS 232 EnableA Reserved EnableA Reserved Control3 Reserved Control3 Reserved Control2 DCD RS 232 Control2 CTS RS 232 Control1 RTS R...

Страница 24: ...has a separate field signal that line should be connected to Enable C SOUT Serial Data Out is used for RS 232 connections SIN Serial Data In is used for RS 232 connections RI Ring Indicator is used f...

Страница 25: ...oltage 2 0 V Input low voltage 0 8 V Polarity Programmable active high or active low Trigger output Voltage range 0 to 5 V TTL Output high voltage 2 4 V at 15 mA source Output low voltage 0 55 V at 10...

Страница 26: ...L Polarity Configurable rising or falling edge Enable Signal type Configurable LVDS or TTL Polarity Configurable active high or active low Control Signal type Configurable LVDS or TTL Polarity Configu...

Страница 27: ...5 6 7 or 8 bits Parity Configurable odd even or disabled Stop bit Configurable enabled or disabled Data transmit ready polarity Configurable active high or active low Ready to send polarity Configurab...

Страница 28: ...Compatibility Emissions EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 EMC EMI CE C Tick and FCC Part 15 Class A Compliant Note For EMC compliance operate thi...

Страница 29: ...Instruments Application Engineers make sure every question receives an answer For information about other technical support options in your area go to ni com services or contact your local branch at n...

Страница 30: ...om calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of...

Страница 31: ...on window or frame that is controlled and defined by software ASIC Application Specific Integrated Circuit A proprietary semiconductor component designed and manufactured to perform a set of specific...

Страница 32: ...umber of horizontal lines needed to represent a frame of video The first field of a frame contains all the odd numbered lines the second field contains all of the even numbered lines FIFO First in fir...

Страница 33: ...expansion bus architecture originally developed by Intel to replace ISA and EISA PCI offers a theoretical maximum transfer rate of 133 Mbytes s pixel Picture element The smallest division that makes u...

Страница 34: ...initialization and set up operations The maximum rate at which the hardware can operate trigger Any event that causes or starts some form of data capture trigger control and mapping circuitry Circuitr...

Страница 35: ...NI resources B 1 delayed acquisition start conditions 3 5 diagnostic tools NI resources B 1 DMA controllers 3 4 documentation conventions used in the manual v NI resources B 1 drivers NI resources B...

Страница 36: ...control integrating with 1 4 multiple tap data formatter 3 3 N National Instruments support and services B 1 NI IMAQ driver software 1 2 NVRAM 3 4 O optional equipment 2 2 P PCI interface specificatio...

Страница 37: ...pment Module 1 3 software controlled start conditions 3 4 SOUT signal table 4 3 specifications clocks A 2 environment A 3 external connections A 1 PCI interface A 3 physical A 3 power requirements A 3...

Отзывы: