![National Instruments IMAQ NI 1450 Series Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/national-instruments/imaq-ni-1450-series/imaq-ni-1450-series_user-manual_708937031.webp)
Chapter 2
Setup and Configuration
©
National Instruments Corporation
2-17
NI 1450 Series Compact Vision System User Manual
Downloading Software onto the NI 1450
1.
In the MAX configuration window, click the
Software
tab. This
window displays the status of the software on the NI 1450.
2.
Click the
Install Software
button.
3.
Select the software to download. For initial installation, make sure all
checkboxes are selected.
4.
Click
OK
.
5.
When prompted, click
Yes
to reboot the NI 1450. This process takes
several seconds.
Acquiring an Image Using LabVIEW Real-Time
To acquire an image using LabVIEW Real-Time, complete the following
steps:
1.
Launch LabVIEW by navigating to
Start»Programs»National
Instruments LabVIEW 7.0
.
2.
Expand the
Execution Target
pull-down listbox and click
Select
Target with Options
.
3.
Enter the new IP address in the
Machine Name/IP
field and click
OK
.
4.
Click the
Open
button.
5.
Navigate to
Program
Files\National
Instruments\
LabVIEW
7.0\examples\IMAQ
.
6.
Double-click
IMAQ1394
examples.llb
and select
Grab.vi
.
7.
Click the Run button to begin acquiring images.
Now that you are acquiring images in LabVIEW, you can use the Vision
Development Module and the installed NI 1450 drivers to process images
and to control inputs and outputs.