National Instruments IC-3173 Скачать руководство пользователя страница 32

Visit the NI Developer Zone at 

http://www.ni.com/zone

 for the latest example programs,

tutorials, technical presentations, and a community area where you can share ideas, questions,
and source code with developers around the world.

Resources for Vision Builder AI Users

Refer to the 

NI Vision Builder for Automated Inspection Tutorial

 to learn how to perform basic

machine vision techniques using Vision Builder AI. You can access the 

NI Vision Builder for

Automated Inspection Tutorial

 and other documentation by selecting 

Start

»

All Programs

»

National Instruments

»

Vision Builder AI

»

Documentation

. You can also access context help

within Vision Builder AI by clicking the 

Show Context Help

 button on the Vision Builder AI

toolbar.

Examples of common Vision Builder AI inspections are installed to the

 <Vision Builder

AI>\Examples

 directory, where <Vision Builder AI> is the location Vision Builder AI is

installed.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on NI trademarks. Other product and

company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI
products/technology, refer to the appropriate location: 

Help

»

Patents

 in your software, the 

patents.txt

 file on your media, or the

National Instruments Patent Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs)

and third-party legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information

 at 

ni.com/

legal/export-compliance

 for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other

import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION
CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in
this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth
in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2016 National Instruments. All rights reserved.

375285A-01

Apr16

Содержание IC-3173

Страница 1: ...rements 24 Software Options 25 BIOS Configuration and System Recovery 25 Entering BIOS Setup 25 BIOS Setup Utility Keyboard Navigation 25 Main Setup Menu 26 Advanced Menu 27 Boot Menu 29 Save Exit Men...

Страница 2: ...s four USB 2 0 ports and two DisplayPort connectors The IC 3173 front panel also includes LEDs for communicating system status and a 44 pin Digital I O port The Digital I O port offers 8 isolated inpu...

Страница 3: ...ured 9 Power Button 10 System Power Connector 11 User Accessible Battery Compartment not pictured 12 RS 232 RS 485 Serial Port 13 USB 3 0 Ports 14 Primary Gigabit Ethernet Port 15 Retention Mounts for...

Страница 4: ...VGA or DVI connector The following figure lists the DisplayPort pins and signals Figure 2 DisplayPort Connector Pin Locations 1 19 20 2 Table 1 DisplayPort Connector Pin Descriptions Pin Signal Name 1...

Страница 5: ...corresponds to the port illuminates When you unplug a PoE device PoE is automatically disabled You can use non PoE Ethernet devices with the PoE enabled Gigabit Ethernet ports A CAT 5e or CAT 6 1000Ba...

Страница 6: ...evice or connector block using a shielded cable NI recommends the following digital I O cables for the IC 3173 Cable Part Number 44 pin D sub male to pigtail cable 156083 03 for 3 meter cable 44 pin D...

Страница 7: ...ted input 14 CISO Common ground reference for isolated inputs and outputs 15 Iso Out 4 General purpose isolated output 16 Diff 0 Bidirectional RS 422 I O negative side or quadrature encoder phase A 17...

Страница 8: ...eral purpose isolated input 36 CISO Common ground reference for isolated inputs and outputs 37 Iso In 4 General purpose isolated input 38 Iso In 5 General purpose isolated input 39 CISO Common ground...

Страница 9: ...d is connected to an output a large counter electromotive force may occur at switching time due to energy stored in the inductive load This flyback voltage can damage the outputs and the power supply...

Страница 10: ...Output External Flyback Diode for Inductive Loads VISO CISO VCC Industrial Controller Load Overcurrent Protection Circuit Connecting to Differential I O The IC 3173 accepts differential RS 422 line dr...

Страница 11: ...ff I O 1 3 3 V 10 k 10 k 10 k 10 k EN EN 7 5 k 7 5 k 7 5 k 7 5 k Figure 8 Connecting Differential Line Drivers Diff In 0 Diff In 0 Phase A Phase A Diff In 1 Diff In 1 Phase B Phase B External Device I...

Страница 12: ...irectional TTL I O Figure 10 TTL Input Output Circuit 100 TTL_OUT TTL_OE TTL_IN 10 k FB TTL I O Power Input Connectors The IC 3173 requires a power supply to power the system and if you want to use th...

Страница 13: ...either RS 485 422 mode or RS 232 mode Set the serial port mode in the BIOS setup utility The serial port is a 10 position RJ50 modular jack which can connect to serial devices such as PLCs scanners a...

Страница 14: ...USB 3 0 Ports The USB ports support common USB peripheral devices such as USB flash drives USB hard drives USB to IDE adapters keyboards mice and USB cameras LabVIEW Real Time usually maps USB mass st...

Страница 15: ...ds mice and USB cameras LabVIEW Real Time usually maps USB mass storage devices to the U V W or X drive starting with the U drive if it is available Refer to the LabVIEW Help for more information Figu...

Страница 16: ...he IC 3173 automatically restarts after an exception After the second exception the IC 3173 remains in the exception state alerting you to resolve the problem Reinstall software on the IC 3173 or cont...

Страница 17: ...about programming this LED PoE LEDs The PoE Power over Ethernet LEDs are located to the left of the PoE ports The following table describes the PoE LED indications Table 12 PoE LED Indications PoE LED...

Страница 18: ...he TCP IP settings when moving the system from one subnet to another or when the current TCP IP settings are invalid When the IC 3173 is in the IP reset state the IP address of the network port resets...

Страница 19: ...ing strap or touching a grounded object such as a computer chassis 1 Use a Phillips head screwdriver to remove the two screws holding the battery cover plate Remove the plate 2 Locate the BATTERY CONN...

Страница 20: ...84 in 46 94 mm 1 85 in 46 17 mm 1 58 in 42 60 mm 1 68 in 28 19 mm 1 11 in 22 72 mm 0 89 in 27 94 mm 1 10 in 30 75 mm 1 21 in 26 95 mm 1 06 in 35 18 mm 1 39 in 30 48 mm 1 20 in 11 45 mm 0 45 in 22 7 mm...

Страница 21: ...Figure 16 Side View Dimensions 15 08 mm 0 20 in 173 99 mm 6 85 in 4 23 mm 0 17 in 167 63 mm 6 60 in 176 94 mm 6 97 in IC 3173 User Manual National Instruments 21...

Страница 22: ...m 3 65 in 4x 6 32 7 00 mm 0 28 in Securing the IC 3173 to a Mount 1 Align the screw holes of the mounting bracket with the four holes on the back of the IC 3173 2 Insert four 6 32 screws and tighten t...

Страница 23: ...Figure 18 Securing a Mounting Bracket to the Device IC 3173 User Manual National Instruments 23...

Страница 24: ...ce Requirements The IC 3173 installation must meet the following space and cabling clearance requirements for optimum cooling Allow 101 6 mm 4 0 in on the top and bottom of the IC 3173 for air circula...

Страница 25: ...must install the LabVIEW FPGA Module to reconfigure the default personality of the IC 3173 FPGA BIOS Configuration and System Recovery You can change the configuration settings for the IC 3173 in the...

Страница 26: ...n setup menu reports the following configuration information BIOS Version and Build Date These values indicate the version of the controller BIOS and the date on which the BIOS was built Embedded Firm...

Страница 27: ...ese settings as the factory default settings provide the most compatible and optimal configuration Hyper Threading This setting specifies whether or not to enable Intel Hyper Threading technology in t...

Страница 28: ...e default value is Turn On When set to Stay Off the IC 3173 returns to the soft off power state after power is restored When set to Turn On the IC 3173 powers on when power is restored Power Button Of...

Страница 29: ...econds This setting specifies the number of seconds the POST waits for a USB device or hub to power on This setting is only visible when the Device Power Up Delay is set to Manual The default value is...

Страница 30: ...specifies the power on state of the keyboard NumLock setting The default value is On Save Exit Menu The Save Exit setup menu includes all available options for exiting saving and loading the BIOS def...

Страница 31: ...8 Refer to the IC 3173 Getting Started Guide for information about installing software and configuring the device Where to Go Next The following documents and resources contain information you may fi...

Страница 32: ...idelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering NI prod...

Отзывы: