background image

Table 13.

 Ethernet LED Indications (Continued)

LED

Status

Indication

 

 

 

Activity/Link

OFF

No link has been established

Solid

A link has been negotiated

Blinking

Activity on the link

Using the RESET Button

Pressing the RESET button resets the processor in the same manner as cycling power. You can
also use the RESET button to troubleshoot network connectivity.
The RESET button is located on the bottom of the controller.
1.

Hold the RESET button for 5 seconds, and then release it to boot the IC-3173 into safe
mode and enable Console Out.

2.

After booting the controller into safe mode, hold the RESET button again for 5 seconds to
enable IP reset, which resets the network adapter to its default configuration.

Safe Mode

When you boot the IC-3173 into safe mode, it launches only the services necessary for
updating its configuration and installing software. To resume normal operations, press the
RESET button for less than 5 seconds.

IP Reset

Use IP reset to reset the TCP/IP settings when moving the system from one subnet to another
or when the current TCP/IP settings are invalid.

When the IC-3173 is in the IP reset state, the IP address of the network port resets to DHCP or
a link-local address. You can then set up a new network configuration for the IC-3173 from a
development machine on the same subnet, or you can connect the IC-3173 directly to the
development computer.

Note

 

By default, the target automatically attempts to connect to the network using

DHCP. If the target is unable to initiate a DHCP connection, the target connects to
the network with a link-local IP address (169.254.x.x).

Replacing the Battery

The IC-3173 contains a user-replaceable battery. The battery compartment is located on the
left side of the device as you look at the device from the front. Take the following steps to
replace the battery:

Caution

 

Before removing the battery cover, disconnect all power connectors and

I/O cables from the device. To prevent damage from electrostatic discharge (ESD),
ground the unit and yourself by using a grounding strap or touching a grounded
object, such as a computer chassis.

18

  | 

ni.com

  | 

IC-3173 User Manual

Содержание IC-3173

Страница 1: ...rements 24 Software Options 25 BIOS Configuration and System Recovery 25 Entering BIOS Setup 25 BIOS Setup Utility Keyboard Navigation 25 Main Setup Menu 26 Advanced Menu 27 Boot Menu 29 Save Exit Men...

Страница 2: ...s four USB 2 0 ports and two DisplayPort connectors The IC 3173 front panel also includes LEDs for communicating system status and a 44 pin Digital I O port The Digital I O port offers 8 isolated inpu...

Страница 3: ...ured 9 Power Button 10 System Power Connector 11 User Accessible Battery Compartment not pictured 12 RS 232 RS 485 Serial Port 13 USB 3 0 Ports 14 Primary Gigabit Ethernet Port 15 Retention Mounts for...

Страница 4: ...VGA or DVI connector The following figure lists the DisplayPort pins and signals Figure 2 DisplayPort Connector Pin Locations 1 19 20 2 Table 1 DisplayPort Connector Pin Descriptions Pin Signal Name 1...

Страница 5: ...corresponds to the port illuminates When you unplug a PoE device PoE is automatically disabled You can use non PoE Ethernet devices with the PoE enabled Gigabit Ethernet ports A CAT 5e or CAT 6 1000Ba...

Страница 6: ...evice or connector block using a shielded cable NI recommends the following digital I O cables for the IC 3173 Cable Part Number 44 pin D sub male to pigtail cable 156083 03 for 3 meter cable 44 pin D...

Страница 7: ...ted input 14 CISO Common ground reference for isolated inputs and outputs 15 Iso Out 4 General purpose isolated output 16 Diff 0 Bidirectional RS 422 I O negative side or quadrature encoder phase A 17...

Страница 8: ...eral purpose isolated input 36 CISO Common ground reference for isolated inputs and outputs 37 Iso In 4 General purpose isolated input 38 Iso In 5 General purpose isolated input 39 CISO Common ground...

Страница 9: ...d is connected to an output a large counter electromotive force may occur at switching time due to energy stored in the inductive load This flyback voltage can damage the outputs and the power supply...

Страница 10: ...Output External Flyback Diode for Inductive Loads VISO CISO VCC Industrial Controller Load Overcurrent Protection Circuit Connecting to Differential I O The IC 3173 accepts differential RS 422 line dr...

Страница 11: ...ff I O 1 3 3 V 10 k 10 k 10 k 10 k EN EN 7 5 k 7 5 k 7 5 k 7 5 k Figure 8 Connecting Differential Line Drivers Diff In 0 Diff In 0 Phase A Phase A Diff In 1 Diff In 1 Phase B Phase B External Device I...

Страница 12: ...irectional TTL I O Figure 10 TTL Input Output Circuit 100 TTL_OUT TTL_OE TTL_IN 10 k FB TTL I O Power Input Connectors The IC 3173 requires a power supply to power the system and if you want to use th...

Страница 13: ...either RS 485 422 mode or RS 232 mode Set the serial port mode in the BIOS setup utility The serial port is a 10 position RJ50 modular jack which can connect to serial devices such as PLCs scanners a...

Страница 14: ...USB 3 0 Ports The USB ports support common USB peripheral devices such as USB flash drives USB hard drives USB to IDE adapters keyboards mice and USB cameras LabVIEW Real Time usually maps USB mass st...

Страница 15: ...ds mice and USB cameras LabVIEW Real Time usually maps USB mass storage devices to the U V W or X drive starting with the U drive if it is available Refer to the LabVIEW Help for more information Figu...

Страница 16: ...he IC 3173 automatically restarts after an exception After the second exception the IC 3173 remains in the exception state alerting you to resolve the problem Reinstall software on the IC 3173 or cont...

Страница 17: ...about programming this LED PoE LEDs The PoE Power over Ethernet LEDs are located to the left of the PoE ports The following table describes the PoE LED indications Table 12 PoE LED Indications PoE LED...

Страница 18: ...he TCP IP settings when moving the system from one subnet to another or when the current TCP IP settings are invalid When the IC 3173 is in the IP reset state the IP address of the network port resets...

Страница 19: ...ing strap or touching a grounded object such as a computer chassis 1 Use a Phillips head screwdriver to remove the two screws holding the battery cover plate Remove the plate 2 Locate the BATTERY CONN...

Страница 20: ...84 in 46 94 mm 1 85 in 46 17 mm 1 58 in 42 60 mm 1 68 in 28 19 mm 1 11 in 22 72 mm 0 89 in 27 94 mm 1 10 in 30 75 mm 1 21 in 26 95 mm 1 06 in 35 18 mm 1 39 in 30 48 mm 1 20 in 11 45 mm 0 45 in 22 7 mm...

Страница 21: ...Figure 16 Side View Dimensions 15 08 mm 0 20 in 173 99 mm 6 85 in 4 23 mm 0 17 in 167 63 mm 6 60 in 176 94 mm 6 97 in IC 3173 User Manual National Instruments 21...

Страница 22: ...m 3 65 in 4x 6 32 7 00 mm 0 28 in Securing the IC 3173 to a Mount 1 Align the screw holes of the mounting bracket with the four holes on the back of the IC 3173 2 Insert four 6 32 screws and tighten t...

Страница 23: ...Figure 18 Securing a Mounting Bracket to the Device IC 3173 User Manual National Instruments 23...

Страница 24: ...ce Requirements The IC 3173 installation must meet the following space and cabling clearance requirements for optimum cooling Allow 101 6 mm 4 0 in on the top and bottom of the IC 3173 for air circula...

Страница 25: ...must install the LabVIEW FPGA Module to reconfigure the default personality of the IC 3173 FPGA BIOS Configuration and System Recovery You can change the configuration settings for the IC 3173 in the...

Страница 26: ...n setup menu reports the following configuration information BIOS Version and Build Date These values indicate the version of the controller BIOS and the date on which the BIOS was built Embedded Firm...

Страница 27: ...ese settings as the factory default settings provide the most compatible and optimal configuration Hyper Threading This setting specifies whether or not to enable Intel Hyper Threading technology in t...

Страница 28: ...e default value is Turn On When set to Stay Off the IC 3173 returns to the soft off power state after power is restored When set to Turn On the IC 3173 powers on when power is restored Power Button Of...

Страница 29: ...econds This setting specifies the number of seconds the POST waits for a USB device or hub to power on This setting is only visible when the Device Power Up Delay is set to Manual The default value is...

Страница 30: ...specifies the power on state of the keyboard NumLock setting The default value is On Save Exit Menu The Save Exit setup menu includes all available options for exiting saving and loading the BIOS def...

Страница 31: ...8 Refer to the IC 3173 Getting Started Guide for information about installing software and configuring the device Where to Go Next The following documents and resources contain information you may fi...

Страница 32: ...idelines at ni com trademarks for information on NI trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering NI prod...

Отзывы: