Required Components

The following items are necessary to set up and use the IC-3173.

IC-3173

One shielded CAT 5 10/100Base-TX, CAT 5e, or CAT 6 1000Base-T Ethernet cable to
connect the device to the development computer or to a network.

Note

 

A CAT 5e or CAT 6 1000Base-T Ethernet cable is required to achieve

1,000 Mbps (Gigabit) Ethernet performance. CAT 5e and CAT 6 Ethernet
cables adhere to higher electrical standards required for Gigabit Ethernet
communication. CAT 5 cables are not guaranteed to meet the necessary
requirements. While CAT 5 cables may appear to work at 1,000 Mbps, CAT 5
cables are likely to cause bit errors resulting in degraded network performance.

Development computer running Microsoft Windows. Refer to the driver or application
development software readme for specific Windows version compatibility.

A compatible power supply, such as the NI PS-16 Power Supply (part number
781094-01)

Optional Equipment

National Instruments offers the following products for use with the IC-3173.

NI PS-15 Power Supply to power the isolated outputs (part number 781093-01).

44-pin D-SUB cable for digital I/O.

44-pin D-SUB male to pigtail cable (part number 156083-03 for 3 meter cable).

44-pin D-SUB male to 44-position D-SUB female cable (part number 156084-03 for
3 meter cable or part number 156084-0R5 for 0.5 meter cable).

DisplayPort to VGA adapter cable (part number 782271-01).

DisplayPort to DisplayPort cable (part number 782989-01 for 1.8 meter cable).

Host-to-host USB cable.

NI I/O Accessory.

Caution

 

To ensure the specified EMC performance, operate this product only

with shielded cables and accessories. Do not use unshielded cables or
accessories unless they are installed in a shielded enclosure with properly
designed and shielded input/output ports and connected to the product using a
shielded cable. If unshielded cables or accessories are not properly installed and
shielded, the EMC specifications for the product are no longer guaranteed.

I/O Accessory and 3 meter 44-pin D-SUB male to 44-position D-SUB female cable
(part number 783327-01).

I/O Accessory and 0.5 meter 44-pin D-SUB male to 44-position D-SUB female
cable (part number 783328-01).

Panel Mounting Kit (part number 784791-01).

10-position modular plug to 9-pin D-sub serial cable for RS-485 or RS-232 (part number
182845-01 for 1 meter cable, part number 182845-02 for 2 meter cable, or part number
182845-03 for 3 meter cable).

IC-3173 Getting Started Guide

  | 

© National Instruments

  | 

7

Содержание IC-3173

Страница 1: ...ortant safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in the documentation Misuse of the device may result in a hazard...

Страница 2: ...imum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines before connection to or disconnection from the device Electromagnetic Compati...

Страница 3: ...tion To ensure the specified EMC performance product installation requires either special considerations or user installed add on devices See the product installation instructions for further informat...

Страница 4: ...r Accessible Battery Compartment not pictured 12 RS 232 RS 485 Serial Port 13 USB 3 0 Ports 14 Primary Gigabit Ethernet Port 15 Retention Mounts for USB 3 0 Ports 16 Retention Mounts for USB 2 0 Ports...

Страница 5: ...tion The C terminals are internally connected to each other 6 Install the power connector into SYS PWR IN on the front panel of the controller and tighten the connector screw flanges to 0 3 to 0 4 N m...

Страница 6: ...f the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 5 Connect the negative lead of the isolated outputs power source to the C terminal of the power...

Страница 7: ...male to pigtail cable part number 156083 03 for 3 meter cable 44 pin D SUB male to 44 position D SUB female cable part number 156084 03 for 3 meter cable or part number 156084 0R5 for 0 5 meter cable...

Страница 8: ...r network device on the same network as the development computer 4 Verify the ACTIVITY LINK LED on the port is on or blinking The device negotiates an IP address when connected to a network with a DHC...

Страница 9: ...tware set a Expand the IC 3173 under Remote Systems b Click the Software item below the IC 3173 in the configuration tree c Click Add Remove Software on the NI MAX toolbar to launch the LabVIEW Real T...

Страница 10: ...words If you forget the password you must contact NI and reformat the controller Troubleshooting The IC 3173 Does Not Appear in MAX The IC 3173 may not be powered Verify that there is system power to...

Страница 11: ...f you are having difficulty detecting the system and setting up the IC 3173 on your network you must configure the firewall to open the TCP UDP ports used by the IC 3173 and the host machine Refer to...

Страница 12: ...ontroller either booted into an unsupported operating system was interrupted during the boot process or detected an unrecoverable software error Continuous blink red This indicates a hardware error An...

Страница 13: ...declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: