Specifications
Specifications are typical for the –25 to 55 °C temperature range unless otherwise noted.
Specifications are subject to change without notice.
Network
Network interface . . . . . . . . . . . . . . . . 10BaseT and 100BaseTX Ethernet
Compatibility. . . . . . . . . . . . . . . . . . . . . IEEE802.3
Communication rates . . . . . . . . . . . . . 10 Mbps, 100 Mbps, auto-negotiated
Maximum cabling distance . . . . . . . . 100 m/segment
Maximum power supplied to
terminal bases . . . . . . . . . . . . . . . . . . . 9 W
Maximum number of banks. . . . . . . . Determined by network topology
Memory
FP-2000 . . . . . . . . . . . . . . . . . . . . . . . . . 32 MB nonvolatile
16 MB DRAM
FP-2010 . . . . . . . . . . . . . . . . . . . . . . . . . 64 MB nonvolatile
32 MB DRAM
FP-2015 . . . . . . . . . . . . . . . . . . . . . . . . . 512 MB nonvolatile
32 MB DRAM
For information about the memory used by the LabVIEW RT module and the operating
system, go to
ni.com/info
and enter
rdfpec
.
©
National Instruments Corporation
15
FP-20xx Quick Start Guide
322759e.qxp 4/22/2004 4:00 PM Page 15