National Instruments FieldPoint FP-1601 Скачать руководство пользователя страница 14

Go to 

ni.com/support

for the most current manuals, examples, and troubleshooting information. 

For telephone support in the United States, create your service request at 

ni.com/ask

and follow the

calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your
local branch office:

Australia 02 612 9672 8846, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599,
Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, 
Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, 
China 86 21 6555 7838, Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11,
France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, 
Malaysia 603 9131 0918, Mexico 001 800 010 0793, Netherlands 31 0 348 433 466, 
New Zealand 64 09 914 0488, Norway 47 0 32 27 73 00, Poland 48 0 22 3390 150, Portugal 351 210 311 210,
Russia 7 095 238 7139, Singapore 65 6226 5886, Slovenia 386 3 425 4200, South Africa 27 0 11 805 8197, 
Spain 34 91 640 0085, Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, Taiwan 886 2 2528 7227,
Thailand 662 992 7519, United Kingdom 44 0 1635 523545

CVI™, FieldPoint™, LabVIEW™, Measurement Studio™, National Instruments™, NI™, and ni.com™ are
trademarks of National Instruments Corporation. Product and company names mentioned herein are
trademarks or trade names of their respective companies. 

For patents covering National Instruments products, refer to the appropriate location: 

Help»Patents

in your software, the 

patents.txt

file on your CD, or 

ni.com/patents

.

© 2001–2003 National Instruments Corporation. All rights reserved.

*322978C-01*

322978C-01

Apr03

322978c.qxd  4/4/2003  4:08 PM  Page 16

Содержание FieldPoint FP-1601

Страница 1: ...P 1601 network module 35 mm DIN rail Two DIN rail locks included Terminal base s I O module s 11 30 VDC power supply Accessories Ethernet cable flathead screwdriver PC running Windows National Instruments FieldPoint Software CD Install the Network Module Mount the module on a DIN rail A Unlock rail clip 1 322978c qxd 4 4 2003 4 08 PM Page 1 ...

Страница 2: ...i com NOTE Do not use spliced DIN rails Use only a single DIN rail B Hook lip on back of module onto top of DIN rail press down and snap into place C Slide module into position and lock rail clip 322978c qxd 4 4 2003 4 08 PM Page 2 ...

Страница 3: ...erminal Base s 2 CAUTION Connect the terminal bases to the network module before applying power to the module Do not connect or disconnect terminal bases while power is applied to the network module A Unlock rail clip B Press base onto rail 322978c qxd 4 4 2003 4 08 PM Page 3 ...

Страница 4: ... sure there are no gaps between terminal bases E You must install DIN rail locks at each end of the bank to ensure reliable connections between terminal bases and network module Two rail locks are included with each network module Place protective cover on last base C Slide base into position and lock rail clip Be careful not to bend any pins 4 FP 1601 Quick Start Guide ni com 322978c qxd 4 4 2003...

Страница 5: ... away from heat sources including network modules and relay modules A Align slots on module with guide rails on base and press module onto base until terminal base latch locks module in place B Repeat for each I O module 3 CAUTION Cascading power defeats isolation Connect the FP 1601 to the Network Connect the FP 1601 to an Ethernet network by connecting the RJ 45 Ethernet port of the FP 1601 to a...

Страница 6: ...amples include output counter relay PWM PG and QUAD modules It is generally best to power each such module by connecting an external power supply to the VSUP and COM terminals Refer to the I O module operating instructions for power requirements detailed wiring diagrams and safe wiring practices 5 Optionally you can connect an FP 1601 directly to a computer using an Ethernet crossover cable Do not...

Страница 7: ...ended Cascaded Power Reduces Isolation No External Power Required Power supply connected to VSUP and COM terminals FP 1601 CAUTION Cascading power from neighboring bases or network modules defeats isolation between cascaded modules CAUTION Cascading power defeats isolation Shades of gray indicate different voltage potentials 322978c qxd 4 4 2003 4 08 PM Page 7 ...

Страница 8: ...g power Make sure the RESET DIP switch is not on Plug in each power supply to the FieldPoint bank You should see the POWER and STATUS LEDs come on After about 5 seconds the STATUS LED begins flashing one flash at a time This indicates that the FP 1601 is ready to be configured If the LEDs do not follow this sequence refer to the FP 1601 User Manual troubleshooting appendix 1 2 3 4 5 6 7 RESET O F ...

Страница 9: ... LabVIEW VIs and examples and the LabWindows CVI instrument driver only if it finds the corresponding development software installed B Close all other applications C Insert the National Instruments FieldPoint Software CD into the CD ROM drive of your computer D Follow the onscreen instructions to complete the installation 8 NOTE If the setup does not launch automatically select Start Run from Wind...

Страница 10: ...gure the FP 1601 For information about configuring the FP 1601 in software refer to the Measurement Automation Explorer Help for FieldPoint Start Programs National Instruments FieldPoint FieldPoint Help 9 10 FP 1601 Quick Start Guide ni com 322978c qxd 4 4 2003 4 08 PM Page 10 ...

Страница 11: ...mber of banks Determined by network topology Power Requirements Power supply range 11 30 VDC Recommended power supply FP 1601 with up to 5 modules 15 W FP PS 4 or equivalent FP 1601 with 6 to 9 modules 20 W Power consumption 4 5 W 1 1 I O module power requirements Physical Characteristics Screw terminal wiring 16 26 AWG copper conductor wire with 7 mm 0 28 in of insulation stripped from the end To...

Страница 12: ...ng standards for safety and electrical equipment for measurement control and laboratory use EN 61010 1 IEC 61010 1 UL 3121 1 UL 61010C 1 CAN CSA C22 2 No 1010 1 For UL and other safety certifications refer to the product label or to ni com Electromagnetic Compatibility CE C Tick and FCC Part 15 Class A Compliant Emissions EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 ...

Страница 13: ...ollows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 EEC NOTE Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product click Declarations of Conformity Information at ni com hardref nsf 109 5 mm 4 31 in 91 44 mm 3 60 in 107 19 mm 4 22 in 322978c qxd 4 4 2003 4 08 P...

Страница 14: ...Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Malaysia 603 9131 0918 Mexico 001 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 64 09 914 0488 Norway 47 0 32 27 73 00 Poland 48 0 22 3390 150 Portugal 351 210 311 210 Russia 7 095 238 7139 Singapore 65 6226 5886 Slovenia 386 3 425 4200 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56...

Отзывы: