Chapter 4
LabVIEW RT Programming
cFP-20xx and cFP-BP-x User Manual
4-6
ni.com
In the RT Target: Access dialog box previously shown, all hosts in
the
site.com
domain can target the RT Engine, with the exception
of all hosts in the
test.site.com
domain. Additionally, the hosts
a.test.site.com
,
b.test.site.com
, and
130.164.123.123
also
can target the RT Engine. The host
public.site.com
does not have
access, even though it is in the
site.com
domain.
The default RT Target: Access settings permit any host machine to target
the RT Engine on the cFP-20
xx
without a password.
Note
If the cFP-20
xx
does not have access to a Domain Name Server (DNS), do not use
domain name entries in the RT Target Access List. Requests to resolve domain names to
IP addresses fail and slow down the system. Place frequently matched entries toward the
bottom of the RT Target Access List to improve system performance.
RT Target: Miscellaneous
Use
RT Target: Miscellaneous
options to launch LabVIEW RT
applications at system startup and to specify the
Downloaded VI Path
.
Complete the following steps to open the RT Target: Miscellaneous
dialog box:
1.
Target LabVIEW RT to the cFP-20
xx
. Refer to the
section for more information about targeting
LabVIEW RT to the cFP-20
xx
.
2.
Select
Tools»Network Options
.
3.
Select
RT Target: Miscellaneous
from the pull-down menu to see the
following dialog box.