![National Instruments DAQCard-6533 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/national-instruments/daqcard-6533/daqcard-6533_user-manual_3584121084.webp)
Chapter 3
Timing Diagrams
3-28
ni.com
Figure 3-27.
Leading-Edge Input State Machine
Wait
For
Space
Wait
For
REQ
Programmable
Delay
Programmable
Delay
Wait
For
REQ
When REQ
Asserted
When 6533 Device has space
for data, input data.*
Clear
ACK
Pulse
When REQ
Unasserted
Initial State: ACK Cleared
Send
ACK
Pulse
* With REQ-edge latching enabled, the data input
is from the last active-going REQ edge.