© National Instruments
|
8-5
Assume that an input terminal has been low for a long time. The input terminal then changes
from low to high, but glitches several times. When the filter clock has sampled the signal high
on N consecutive edges, the low to high transition is propagated to the rest of the circuit. The
value of N depends on the filter setting; refer to Table 8-1.
The filter setting for each input can be configured independently. On power up, the filters are
disabled. Figure 8-3 shows an example of a low to high transition on an input that has a custom
filter set to N = 5.
Figure 8-3.
Filter Example
Enabling filters introduces jitter on the input signal. The maximum jitter is one period of the
timebase.
When a RTSI input is routed directly to PFI, the X Series device does not use the filtered version
of the input signal.
Table 8-1.
Filters
Filter Setting
Filter Clock
N (Filter
Clocks
Needed to
Pass Signal)
Pulse Width
Guaranteed
to Pass Filter
Pulse Width
Guaranteed
to Not Pass
Filter
None
—
—
—
—
90 ns
(short)
100 MHz
9
90 ns
80 ns
5.12 µs
(medium)
100 MHz
512
5.12 µs
5.11 µs
2.56 ms
(high)
100 kHz
256
2.56 ms
2.55 ms
Custom
User
configurable
N
N/timebase
(N - 1)/
timebase
1
2
3
1
4
1
2
3
4
5
RT
S
I, PFI, or
PXI_
S
TAR Termin
a
l
Filtered inp
u
t goe
s
high when termin
a
l
i
s
sa
mpled high on
five con
s
ec
u
tive filter
clock
s
.
Filter Clock
Filtered Inp
u
t