![National Instruments DAQ PCI-1200 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/national-instruments/daq-pci-1200/daq-pci-1200_user-manual_708965051.webp)
Chapter 3
Signal Connections
©
National Instruments Corporation
3-29
Mode 1 Output Timing
The timing specifications for an output transfer in mode 1 are as follows:
Figure 3-18.
Mode 1 Timing Specifications for Output Transfers
Name
Description
Minimum
Maximum
T1
WRT* = 0 to INTR = 0
—
450
T2
WRT* = 1 to output
—
350
T3
WRT* = 1 to OBF* = 0
—
650
T4
ACK* = 0 to OBF* = 1
—
350
T5
ACK* pulse width
300
—
T6
ACK* = 1 to INTR = 1
—
350
All timing values are in nanoseconds.
WRT*
OBF*
INTR
ACK*
DATA
T1
T2
T3
T4
T5
T6