manualshive.com logo in svg
background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание cFP-RLY-421

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...network module you are using Features The cFP RLY 421 is a Compact FieldPoint relay output module with the following features Eight single pole single throw SPST relay channels Switches up to 1 5 A at 40 VDC or 250 VAC 40 to 55 C operation 250 Vrms CAT II continuous channel to ground isolation verified by 2 300 Vrms 5 s dielectric withstand test Hot swappable Installing the cFP RLY 421 The cFP RLY...

Страница 3: ...ane 3 Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the captive screws to 1 1 N m 10 lb in of torque The nylon coating on the screws prevents them from loosening Figure 1 Installing the cFP RLY 421 1 cFP I O Module 2 Captive Screws 3 cFP Controller Module 4 Screw Holes 5 cFP Backplane 4 4 3 2 1 5 5 cFP RLY 421 new fm Page 2 Tuesday October 11 2005 11 50...

Страница 4: ...y by qualified personnel adhering to local electrical standards Each relay channel of the cFP RLY 421 has two terminals one NO normally open and one IC isolated common Table 1 lists the terminal assignments for the signals of each channel All of the COM terminals are connected internally and all of the VSUP terminals are connected internally NI does not recommend using the VSUP and COM terminals w...

Страница 5: ...t acting fuse suitable for the load at the IC terminal to protect the module and the load from damage Figure 2 Connecting a Load The cFP RLY 421 has eight SPST electromechanical relays The power up state is off open to ensure safe installation In the ON Table 2 VSUP and COM Terminal Assignments VSUP COM 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 To next channel cFP RLY 421 IC NO V C VSUP COM ...

Страница 6: ... prevent excessively high voltage from being applied across the contacts The MOVs are located between the NO and IC contacts of each relay However National Instruments recommends installing protection circuits across inductive loads The flyback protection causes a small leakage current which is detailed in the Specifications section Refer to the NI Switches Help for information about selecting and...

Страница 7: ...sible parts or circuits Never try to use any isolation product between human accessible parts such as DIN rails or monitoring stations and circuits that can be at hazardous potentials under normal conditions unless the product is specifically designed for such an application as is the cFP RLY 421 Even though the cFP RLY 421 is designed to handle applications with hazardous potentials follow these ...

Страница 8: ... it Connect the backplane PE ground terminal to the system safety ground using 14 AWG 1 6 mm wire with a ring lug Use the 5 16 in panhead screw shipped with the backplane to secure the ring lug to the backplane PE ground terminal The cFP RLY 421 is a UL Recognized component The entire Compact FieldPoint system must be installed in a UL Listed suitably rated NEMA or IP enclosure for safe use Figure...

Страница 9: ...ironmental ratings Refer to the Specifications section Refer to the product label for manufacturing location This product must be installed in an enclosure rated at least IP 54 Specifications The following specifications are typical for a range of 40 to 55 C unless otherwise noted All specifications are subject to change without notice Relay Characteristics Number of channels 8 Relay type SPST non...

Страница 10: ... 8 µA At 120 VDC 0 12 µA Expected life Mechanical 2 107 operations min Electrical 100 000 operations Maximum switching frequency Mechanical 20 operations per second Electrical 1 operation per second at maximum load Relay operate time 8 ms Relay release time 4 ms Relay bounce time 4 ms Contact material Gold plated silver cadmium oxide Physical Indicators Green POWER and READY indicators 8 green out...

Страница 11: ... Humidity 10 to 85 RH noncondensing Maximum altitude 2 000 m at higher altitudes the isolation voltage ratings must be lowered Pollution Degree 2 Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CAN CSA C22 2 No 61010 1 For UL hazardous location and oth...

Страница 12: ... as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 EEC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column cFP RLY 421 new ...

Страница 13: ...so has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599...

Страница 14: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: