The
Digital Input Triggering Signals
section of Chapter 4,
–
The
Digital Output Triggering Signals
section of Chapter 4,
•
Independent Data Streams
—The cDAQ controller supports seven independent
high-speed data streams, which allow for up to seven simultaneous hardware-timed tasks,
such as analog input, analog output, buffered counter/timers, and hardware-timed digital
input/output.
•
PFI Signals
—The PFI signals provide access to advanced features such as triggering,
synchronization, and counter/timers. You can also enable a programmable debouncing
filter on each PFI signal that, when enabled, samples the input on each rising edge of a filter
clock. PFI signals are available through parallel digital input and output modules installed
in up to two controller slots. Refer to the
section of Chapter 4,
, for more information.
•
Flexible Counter/Timers
—The cDAQ controller includes four general-purpose 32-bit
counter/timers that can be used to count edges, measure pulse-widths, measure periods and
frequencies, and perform position measurements (encoding). In addition, the
counter/timers can generate pulses, pulse trains, and square waves with adjustable
frequencies. You can access the counter inputs and outputs using parallel digital I/O
modules installed in up to two slots. Refer to Chapter 5,
, for more information.
Processor and Ports
Refer to the specifications document for your cDAQ controller for information about the
processors on the cDAQ controller. Refer to the
information about using the various ports on the cDAQ controller.