manualshive.com logo in svg
background image

 

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. 
Refer to the 

Terms of Use

 section on 

ni.com/legal

 for more information about National 

Instruments trademarks. Other product and company names mentioned herein are trademarks or trade 
names of their respective companies. For patents covering National Instruments products, refer to the 
appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your CD, or 

ni.com/patents

.

© 2005–2006 National Instruments Corporation. All rights reserved.

371566B-01

Mar06

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20,  Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 6555 7838, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11,  France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, India 91 80 41190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, 
Korea 82 02 3451 3400,  Lebanon 961 0 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 0800 553 322, 
Norway 47 0 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 095 783 68 51, 
Singapore 1800 226 5886, Slovenia 386 3 425 4200, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 0 8 587 895 00,  Switzerland 41 56 200 51 51, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
United Kingdom 44 0 1635 523545

Содержание 9211A

Страница 1: ...9211 9211A data acquisition device provides a USB interface for four channels of 24 bit thermocouple inputs with integrated signal conditioning The NI USB 9211 consists of two components an NI 9211 mo...

Страница 2: ...the combined system may be limited Refer to the Specifications section for more details Hot Surface This icon denotes that the component may be hot Touching this component may result in bodily injury...

Страница 3: ...evices and circuits connected to the module are properly insulated from human contact Caution When module terminals are live with hazardous voltages make sure that the terminals are not accessible by...

Страница 4: ...d the USB 9161 9162 carrier are packaged separately Refer to Figure 3 while completing the following assembly steps 1 Make sure that no signals are connected to the NI 9211 module and the USB cable is...

Страница 5: ...3 Module Installation 4 Squeeze the latches and insert the NI 9211 module into the carrier 5 Press firmly on the connector side of the NI 9211 module until the latches lock the module into place as sh...

Страница 6: ...o the USB 9211 9211A and the other end into an available USB port on the computer LED Indicator The LED indicator indicates device status Table 2 LED State Device Status LED State Device Status Not li...

Страница 7: ...the thermocouple TC The USB 9211 9211A also has a common terminal COM that is internally connected to the isolated ground reference of the module Caution The high voltage screw terminal backshell mus...

Страница 8: ...shell must be installed when using hazardous voltages 42 4 Vpk 60 VDC Refer to Figure 7 while completing the following steps 1 Connect the leads to the screw terminal and secure with the strain relief...

Страница 9: ...e TC and COM terminals and between the TC and COM terminals Each channel is filtered and then sampled by a 24 bit analog to digital converter ADC There is a current source between the TC and TC termin...

Страница 10: ...t errors depend in part on the thermocouple type the temperature being measured the accuracy of the thermocouple and the cold junction temperature Using the Autozero Channel The USB 9211 9211A has an...

Страница 11: ...res account for gain errors offset errors differential and integral nonlinearity quantization errors noise errors and isothermal errors The figures do not account for the accuracy of the thermocouple...

Страница 12: ...1000 0 2 3 4 Max over Temp Range with Autozero Max at Room Temp Range without Autozero Typ over Temp Range with Autozero Error C Measured Temperature C 1 200 0 200 400 600 800 1000 1200 0 1 2 3 4 Max...

Страница 13: ...hermal gradient generated across the terminals can cause the terminals of different channels to be at different temperatures so the resulting measurement creates errors not only in absolute accuracy b...

Страница 14: ...ct any extension wires to thermocouple wires use wires made of the same conductive material Specifications The following specifications are typical at 25 C unless otherwise noted All voltages are rela...

Страница 15: ...50 60 Hz Overvoltage protection 30 V between any input and common Differential input impedance 20 M Input current 50 nA Input noise 1 Vrms Gain error 0 05 max at 25 C 0 06 typ over temperature 0 1 max...

Страница 16: ...m 5 51 in 3 37 in 0 99 in Weight Approx 350 g 12 3 oz Screw terminal wiring 12 to 24 AWG wire with 10 mm 0 39 in of insulation stripped from the end Torque for screw terminals 0 5 0 6 N m 4 4 5 3 lb i...

Страница 17: ...and electronics Isolation Channel to channel No isolation between channels Channel to earth ground Withstand 2 300 Vrms 5 seconds max Continuous 250 Vrms Measurement Category II Measurement Category I...

Страница 18: ...duct meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 E...

Страница 19: ...National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow th...

Отзывы: