background image

Removing the Adapter Module

Complete the following steps to remove the adapter module from the FlexRIO FPGA module.

Disabling the Adapter Module in LabVIEW FPGA

To properly remove an adapter module from the FlexRIO FPGA module, you must disable the
adapter module within the LabVIEW FPGA user interface. To disable the adapter module
within LabVIEW, complete the following steps.
1.

In your LabVIEW 

Project Explorer

 window, right-click the 

IO Module

 item under the

FPGA Target and select 

Properties

 to display the 

IO Module Properties

 dialog box.

2.

Click the 

Status

 category to view the adapter module 

Status

 dialog.

3.

Deselect the checkbox for 

Enable IO Module Power

. When this option is deselected,

firmware tristates the FlexRIO I/O and disables all adapter module power rails.

4.

Click 

OK

.

Uninstalling the Module

Caution

 

If the module has been in use, it may exceed safe handling temperatures

and cause burns. Allow the module to cool before removing it from the chassis.

1.

Disconnect any cables from the module front panel connectors.

Caution

 

Disconnect any external clock or digital connections to the device

front panel. Applying external signals while the device is powered off may
cause damage.

2.

Power off the chassis.

3.

Ground yourself with a grounding strap or touch a grounded metal surface.

4.

Unlatch the module by pushing down on the ejector handle.

5.

Hold the module by the ejector handle and remove it from the slot.

Store the module in the original antistatic packaging when not in use to avoid damage.

Installing Accessories

The NI SMB-2152 is a breakout box accessory for debugging your NI 5741. The NI part
number for the NI SMB-2152 is 189408F-08L.

Related Information

For information about installing the NI SMB-2152, refer to the NI SMB-2152 Installation
Guide at ni.com/manuals.

8

  | 

ni.com

  | 

NI 5741 Getting Started Guide

Содержание 5741

Страница 1: ...gnals for the NI 5741R which is composed of a FlexRIO FPGA module and the NI 5741 Caution The protection provided by the NI 5741 can be impaired if it is used in a manner not described in this documen...

Страница 2: ...omagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test...

Страница 3: ...n Locations Table 1 FlexRIO Documentation Locations and Descriptions Document Location Description Getting started guide for your FPGA module Available from the Start menu and at ni com manuals Contai...

Страница 4: ...able in NI Example Finder In LabVIEW click Help Find Examples Hardware Input and Output FlexRIO Contains examples of how to run FPGA VIs and Host VIs on your device IPNet Located at ni com ipnet Conta...

Страница 5: ...s for complete specifications Installing the Application Software and Driver Before installing your hardware you must install the application software and instrument driver Visit ni com info and enter...

Страница 6: ...n adapter module skip step 5 5 Install NI FlexRIO Adapter Module Support Refer to the NI FlexRIO Adapter Module Support Readme on the NI FlexRIO Adapter Module Support installation media for system re...

Страница 7: ...7 01 included in the NI 5741 packaging 3 Launch LabVIEW to begin configuring your NI FlexRIO system Connecting Cables Use any shielded50 SMA cable to connect signals to the connectors on the front pan...

Страница 8: ...tion If the module has been in use it may exceed safe handling temperatures and cause burns Allow the module to cool before removing it from the chassis 1 Disconnect any cables from the module front p...

Страница 9: ...al descriptions for the NI 5741 Figure 4 NI 5741 Front Panel Connectors AO 0 15 PFI 0 AUX I O 1 MS s 16 Bit Analog Output Caution To avoid permanent damage to the NI 5741 disconnect all signals connec...

Страница 10: ...2 23 24 25 26 27 28 29 30 31 32 33 34 No Connect GND No Connect GND No Connect GND No Connect RESERVED No Connect GND No Connect GND No Connect GND No Connect GND AO 15 GND AO 13 GND AO 11 GND AO 9 GN...

Страница 11: ...Port 1 2 Bidirectional SE DIO data channel 11 GND Ground reference for signals 12 DIO Port 1 3 Bidirectional SE DIO data channel 13 PFI 0 Bidirectional SE DIO data channel 14 NC No connect 15 PFI 1 B...

Страница 12: ...allows you to insert HDL IP into an FPGA target enabling VHDL code to communicate directly with an FPGA VI Socketed CLIP provides the same IP integration of the user defined CLIP but it also allows th...

Страница 13: ...IP User Defined CLIP Fixed I O DRAM 0 CLIP Socket Socketed CLIP DRAM 1 CLIP Socket Socketed CLIP Fixed I O Fixed I O DRAM 0 DRAM 1 If you are using an NI FlexRIO FPGA module with a Kintex 7 FPGA refer...

Страница 14: ...ixteen 16 bit analog output channels eight bidirectional DIO channels four bidirectional PFI channels and one bidirectional trigger line The following figure shows the relationship between the NI 5741...

Страница 15: ...ation programming interface API about hardware features or review device specifications more about your products through ni com the application development environment ADE for your application This it...

Страница 16: ...1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact inf...

Отзывы: