SCXI-1162 Cabling
Appendix E
SCXI-1162 User Manual
E-16
© National Instruments Corporation
4. Connect another ribbon cable to the chassis extender connector that is in the middle of the
SCXI-1350.
5. Plug the SCXI-1350 into the back of an SCXI module in the first chassis so that the module
rear connector mates with the front connector on the SCXI-1350 adapter board. When you
are connecting to an SCXI-1162, be sure to set the jumpers for either a DIO-type or an
MIO-type board as needed.
6. Screw the rear panel to the threaded strips in the rear of the chassis.
7. Connect the loose end of the ribbon cable from step 4 into the rear connector of the second
SCXI-1350, and install the adapter board.
8. Continue until all chassis are connected. You do not need to connect anything to the middle
connector of the SCXI-1350 adapter board in the last chassis.
SCXI-1343 Rear Screw Terminal Adapter
You use the SCXI-1343 universal adapter to adapt custom wiring to the SCXI-1162. The
SCXI-1343 has screw terminals and solder pads for signal connection. A strain relief is on the
outside of the rear panel.
Table E-6. SCXI-1343 Pin Connections
Rear Signal
SCXI-1162 Use
Connector Pin
Parallel
Serial
Connection
1
No Connect
In (23)
Solder pad
2
No Connect
Screw terminal
3
No Connect
In (22)
Screw terminal
4
No Connect
Screw terminal
5
No Connect
In (21)
Screw terminal
6
No Connect
Screw terminal
7
No Connect
In (20)
Screw terminal
8
No Connect
Screw terminal
9
No Connect
In (19)
Screw terminal
10
No Connect
Screw terminal
11
No Connect
In (18)
Screw terminal
12
No Connect
Screw terminal
13
No Connect
In (17)
Screw terminal
14
No Connect
Screw terminal
15
No Connect
In (16)
Screw terminal
16
No Connect
Screw terminal
17
No Connect
In (15)
Screw terminal
18
No Connect
Screw terminal
19
No Connect
In (14)
Screw terminal
20
No Connect
Solder pad
21
No Connect
In (13)
Solder pad
22
No Connect
Solder pad
(continues)