INTELLIREAM
®
MP
pg.
50
E.5 NGFS Robot Programming
with Nozzle Detect
The following flowchart describes the
recommended programming sequence
when a Nozzle Detect option is installed
with a Nozzle Gas Flow Sensor. Note: the
target position must also comply within the
sensing range (1.5 mm) of the Nozzle
Detect sensor.
Errors:
1.
Intelliream
®
Error from previous Cycle
2.
Nozzle presence undetected
3.
Gas flow turn-on undetected
4.
Gas flow turn-off undetected
5.
Nozzle presence unexpected
Move
to “ Flow
Sense” Target position
“Error” on?
Halt for Error
Turn On Gas
Move
to Approach
Position
Move
to Approach
Position
“Complete” off?
Turn Off Gas
Flow Detected.
Turn Off Gas
Error
1
Nozzle
Detect Error
2
Nozzle Detected
Flow Error
3
END
“Complete” on?
Nozzle
Detect Error
5
YES
YES
YES
NO
NO
NO
NO
“Error” off?
NO
Flow Error
4
“Complete” on?
AND
“Error” off?
YES
(2 sec timeout)
(1 sec timeout)