3-2
Radiated Emission and Immunity testing
3.1.5 The meter receiver
The meter receiver is typically either a radio receiver or a spectrum
analyzer. Either a 120 kHz bandwidth and an output indication calibrated in
dB
μ
V are required.
The calculation of the measured E-field signal level is given by:
where:
m
V
dB
E
μ
=Corresponding Electric field
(
)
V
dB
S
μ
= Measured signal strength
( )
dB
C
1
= Preamplifier interconnecting cable
( )
dB
PA
= Preamplifier gain
( )
dB
C
2
= Interconnecting cable loss
m
dB
AF
1
= Antenna factor
Fig. 3-1
Radiated emission test setup
(
)
( )
( )
( )
+
+
−
+
=
m
dB
AF
dB
C
dB
PA