14
W415-1004 / B / 08.10.12
3.7 ELBOW VENT LENGTH VALUES
15.1
FEET
INCHES
1° 0.03
0.5
15° 0.45 6.0
30° 0.9 11.0
45° 1.35 16.0
90°*
2.7
32.0
* The
fi
rst 90° offset has a zero value and is shown in the formula as - 90°
3.8 TOP EXIT HORIZONTAL TERMINATION
(H
T
) < (V
T
)
Simple venting configuration (only one 90° elbow)
See graph to determine the required vertical rise
V
T
for the
required horizontal run
H
T
.
0
2.5
5
7.5
10
12.5
15
40
10
20
30
17.5
20
35
REQUIRED
VERTICAL
RISE IN
FEET
V
T
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
H
T
For vent configurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 35 feet
Example:
V
1
= 3 FT
V
2
= 8 FT
V
T
=
V
1
+ V
2
= 3 + 8 = 11 FT
H
1
= 2.5 FT
H
2
= 2 FT
H
R
=
H
1
+ H
2
= 2.5 + 2 = 4.5 FT
H
O
= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT
H
T
=
H
R
+ H
O
= 4.5 + 5.4 = 9.9 FT
H
T
+ V
T
= 9.9 + 11 = 20.9 FT
Formula 1:
H
T
< V
T
9.9 < 11
Formula 2:
H
T
+ V
T
< 35 FT
20.9 < 35
Since both formulas are met, this vent configuration is acceptable.
90°
90°
90°
V
1
V
2
H
1
H
2
The shaded area within the lines represents acceptable
values for
H
T
and
V
T
16.6A
Содержание Vittoria GD19N
Страница 53: ...53 W415 1004 B 08 10 12 16 0 SERVICE HISTORY 43 1 ...
Страница 54: ...54 W415 1004 B 08 10 12 17 0 NOTES 44 1 ...
Страница 55: ...55 W415 1004 B 08 10 12 44 1 ...
Страница 56: ...56 W415 1004 B 08 10 12 ...
Страница 57: ...56 W415 1004 B 08 10 12 ...