W415-0619 / A /08.09.07

 PG 2-5  INTRODUCTION

 

  

 

  Warranty

  

 

  Dimensions

  

 

  General Instructions

  

 

  General Information

   

 

   Care of Glass & Plated Parts

5-6  

VENTING

  

 

  Venting Lengths 

  

 

  Air Terminal Locations

   

7-9  

INSTALLATION/FRAMING

   

 

   Wall & Ceiling Protection

   

 

   Using Flexible Vent Components

   

 

   Horizontal Air Terminal Installation

   

 

   Fireplace Vent Connection

  

 

  Gas Installation

  

 

  Framing

  

 

  Nailing Tab Installation

   

 

   Clearance to Combustibles

   

9  

ELECTRICAL 

CONNECTION

  

 

   Hard Wiring Connections

WARNING

•  Do not burn wood or other materials in this 

fi

 replace.

•  Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns  

  or clothing ignition. Supervise young children when they are in the same room as the 

fi

 replace.

•  Clothing or other 

fl

 ammable material should not be placed on or near the 

fi

 replace.

•  Due to high temperatures, the 

fi

 replace should be located out of traf

fi

 c and away from furniture and draperies.

•  Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.

•  Even after the 

fi

 replace is out, the glass and/or screen will remain hot for an extended period of time.

•  Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These    

  screens and guards must be fastened to the 

fl

 oor.

•  Any safety screen or guard removed for servicing must be replaced prior to operating the 

fi

 replace.

•  It is imperative that the control compartment and burner in the 

fi

 replace and venting system are kept clean. The 

fi

 replace and its    

  venting system should be inspected before use and at least annually by a quali

fi

 ed service person. More frequent cleaning  

 

  may be required due to excessive lint from carpeting, bedding material, etc. The 

fi

 replace area must be kept clear and free from    

  combustible materials, gasoline and other 

fl

 ammable vapours and liquids.

•  Under no circumstances should this 

fi

 replace be modi

fi

 ed.

• This 

fi

 replace must not be connected to a chimney 

fl

 ue pipe serving a separate solid fuel burning appliance.

•  Do not use this 

fi

 replace if any part has been under water. Immediately call a quali

fi

 ed service technician to inspect the 

fi

 replace    

  and to replace any part of the control system and any gas control which has been under water.

•  Do not operate the 

fi

 replace with the glass door removed, cracked or broken. Replacement of the glass should be done by a  

 

  licensed or quali

fi

 ed service person.

•  Do not strike or slam shut the 

fi

 replace glass door.

•  The glass door must be kept closed while the 

fi

 replace is operating to prevent exhaust fumes containing carbon monoxide,  

 

  from entering into the home.  Temperatures of the exhaust escaping through this opening can also cause the surrounding  

 

  combustible materials to overheat and catch 

fi

 re.

•  Only doors / optional fronts certi

fi

 ed with the unit are to be installed on the appliance.

TABLE of CONTENTS

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

NOTE:  Changes, other than editorial, are denoted by a line in the margin.

This appliance may be installed as an OEM installation in a manufactured home (USA 
only) or mobile home and must be installed in accordance with the manufacturers 
instructions and the Manufactured Home Construction and Safety Standard, Title 24 
CFR, Part 3280 in the United States or in the Mobile Home Standard, CAN/CSA Z240 
MH, Series in Canada.
This appliance is only for use with the type of gas indicated on the rating plate.  This 
appliance is not convertible for use with other gases, unless a certi

fi

 ed kit is used.

This appliance may be installed in an aftermarket, permanently located, manufactured 
home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.  This 
appliance is not convertible for use with other gases, unless a certi

fi

 ed kit is used.

10  

FINISHING

  

 

  Door Removal 

  

 

  Glass Removal

  

 

  Frame Installation

  

 

  Light Installation

 11  

OPERATING INSTRUCTIONS

 

 

 

 12  

MAINTENANCE

   

 

   Gas Pressure Adjustment

  

 

  Venturi Adjustment

 13  

REPLACEMENTS

 

  

 Replacement 

Parts

   

 

  Flexible Vent Kits

  

 

  Terminal Kits

  

 

  Accessories 

 14   

TROUBLE SHOOTING GUIDE

 15   

FIREPLACE SERVICE HISTORY

16  

NOTES

Содержание TORCH GT8N

Страница 1: ...losion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO I...

Страница 2: ...ected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediately call a qualified service technician to inspect the f...

Страница 3: ...louring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanical breakage of PHAZER logs and embers nor any venting components used in the installation...

Страница 4: ...ace shall be installed on a metal or wood panel extending the full width and depth Purge all gas lines with the glass door of the fireplace open Assure that a continuous gas flow is at the burner befo...

Страница 5: ...conjunction with the GD178 wall terminal kit use either the 5 foot vent kit GDT5 or the 10 foot vent kit GDT10 These kits allow for extended horizontal venting of the fireplace The maximum allowable v...

Страница 6: ...6 W415 0619 A 08 09 07 N B B G A F C H H L K J M FIGURE 3...

Страница 7: ...inished wall surface Apply a heavy bead of the high temperature sealant Slip the vent pipe a minimum of 2 over the inner sleeve of the air terminal and secure with 3 8 screws 3 Using the 5 diameter fl...

Страница 8: ...l sheetrock as you would finish any other outside wall of a home This will ensure that clearance to combustibles is maintained within the cavity Proceed once the vent installation is complete Note All...

Страница 9: ...ed This fireplace must be electrically connected and grounded in accordance with local codes In the absence of local codes use the current CSAC22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA...

Страница 10: ...he top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door out from the retainer along the bottom of the door DOOR REMOVAL FINISHING FIGURE 16 GLASS RE...

Страница 11: ...plier s instructions If you cannot reach your gas supplier call the fire department 1 STOP Read the safety information located above 2 Turn off all electric power to the fireplace 3 This fireplace is...

Страница 12: ...ear and free of combustible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 Keep the control compartment burner and air sh...

Страница 13: ...32 W175 0271 COUPLER KIT Contact your dealer for questions concerning prices and availability of replacement parts Normally all parts can be ordered through your Napoleon dealer or distributor When or...

Страница 14: ...Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal venting White grey film forms Sulphur f...

Страница 15: ...15 W415 0619 A 08 09 07 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...