31
W415-0434 / G / 08.08.11
6.2 DOOR CLOSING AND OPENING
Open the valve control door. Hook the top and bottom door latches, located
at the right side of the door into the corresponding slots in the door.
The door latch holes are elongated for door levelling. To level the door, it
may need to be lifted up at the right side before latching to ensure the door
is level.
!
WARNING
FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE
ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE
PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED
IGNITION MAY OCCUR.
THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE.
76.1A
6.3 LOG SHIPPING BRACKET
Before installing the logs, you must
fi
rst remove the log ship-
ping bracket. Loosen the securing screw indicated. Slide the
bracket to the right and lift up to remove.
This appliance does not include decorative brick panels, however, panels are required.
Panel kits are sold separately. Consult your local authorized dealer / distributor. See “REPLACEMENT PARTS
- ACCESSORIES” section.
The charcoal strips have been shipped in place. Protective foam must be removed before operation.
Log colours may vary. During initial use of the appliance, the colours will become more uniform as colour
pigments burn in during the heat activated curing process.
Blocked burner ports can cause an incorrect
fl
ame pattern.
SCREW
LOG SHIPPING
BRACKET
6.4 DECORATIVE
PANELS
6.5 CHARCOAL
STRIPS
6.6 LOG
PLACEMENT