To operate this hi-effi ciency appliance as a basic system, the blower is not required, however, to enhance its
effi ciency a blower is recommended.
2.6 HI-EFFICIENCY
HEATING
2.6.1 HOT AIR GRAVITY VENT SYSTEM (NZ220)
ALL HOT AIR GRAVITY VENTS MUST BE INSULATED.
May be used to distribute heat to an
adjoining room (located either above,
or beside the room containing the
appliance) by way of vents, eliminating
the need of an additional blower.
While this system may be used in
conjunction with the optional blowers,
it could reduce the flow of hot air
being distributed to additional rooms.
It must be experimented with and the
dampers adjusted manually to suit your
requirements. This may take a few
attempts; thereafter adjustments should
no longer be required as is normally
experienced with your central heating
system registers.
No more than
two
hot air gravity vents can be installed to
appliance. Individual vent runs are not to
exceed 10 feet (3m).
5 FT (1.5M)
MINIMUM
FROM FLOOR
5 FT (1.5M)
MINIMUM
FROM FLOOR
GROUND FLOOR
12” (304.8MM)
MINIMUM PIPE
TO CEILING
NO
DUCTING
GRAVITY VENT
OPTION (1 DUCT)
GRAVITY VENT
OPTION (2 DUCTS)
CENTRAL HEATING &
GRAVITY VENT OPTION
GRAVITY VENT OPTION
SIDES
ONLY
When installed with a masonry chimney, the hot air gravity and central heating system can only be installed off the sides.
*
*