Napoleon GI3014-N Скачать руководство пользователя страница 1

WS-415-44 /11.06.98

GAS INSERT

GAS INSERT

GAS INSERT

GAS INSERT

GAS INSERT

INST

INST

INST

INST

INSTALLA

ALLA

ALLA

ALLA

ALLATION AND OPERA

TION AND OPERA

TION AND OPERA

TION AND OPERA

TION AND OPERATION INSTRUCTIONS FOR

TION INSTRUCTIONS FOR

TION INSTRUCTIONS FOR

TION INSTRUCTIONS FOR

TION INSTRUCTIONS FOR

GAS-FIRED 

GAS-FIRED 

GAS-FIRED 

GAS-FIRED 

GAS-FIRED   VENTED ROOM HEA

 VENTED ROOM HEA

 VENTED ROOM HEA

 VENTED ROOM HEA

 VENTED ROOM HEATER

TER

TER

TER

TER

NATURAL GAS  MODEL 

      GI3014-N / GI3014B-N

GI3014-N / GI3014B-N

GI3014-N / GI3014B-N

GI3014-N / GI3014B-N

GI3014-N / GI3014B-N

PROPANE GAS  MODEL 

      GI3014-P / GI3014B-P

GI3014-P / GI3014B-P

GI3014-P / GI3014B-P

GI3014-P / GI3014B-P

GI3014-P / GI3014B-P

GAS-ZERO CLEARANCE WHEN INSTALLED WITH GI-700 KIT

WITHOUT GI-700 KIT INSTALL RECESSED INTO A WOODBURNING NON-COMBUSTIBLE FIREPLACE

CERTIFICATION LABEL AFFIXED TO UNDERSIDE OF FRESH AIR DAMPER

INST

INST

INST

INST

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33 AND ANSI Z21.88 RESPECTIVELY FOR VENTED GAS FIREPLACE HEATERS

Fax: (705)722-6031  EMAIL: [email protected]

WEB: www.napoleon.on.ca

Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,

Barrie, On., Canada  L4M 4Y8  (705)721-1212

R-2000

W

W

W

W

WARNING:

ARNING:

ARNING:

ARNING:

ARNING:      If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

FOR YOUR SAFETY

FOR YOUR SAFETY

FOR YOUR SAFETY

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of

this or any other appliance.

WHA

WHA

WHA

WHA

WHAT

T

T

T

T  T

  T

  T

  T

  TO DO IF YOU SMELL

O DO IF YOU SMELL

O DO IF YOU SMELL

O DO IF YOU SMELL

O DO IF YOU SMELL GAS:

 GAS:

 GAS:

 GAS:

 GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your building.

•  Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
•  If you cannot reach your gas supplier, call
the fire department.

Installation and service must be performed by a qualified installer, service agency

or the gas supplier.

Содержание GI3014-N

Страница 1: ...LER THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER ALLER THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STAND...

Страница 2: ...rk however requires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLE...

Страница 3: ...sventingsystemshouldbein spectedbeforeuseandatleastannuallybyaquali fiedserviceperson Morefrequentcleaningmay berequiredduetoexcessivelintfromcarpeting beddingmaterial etc Thefireplaceareamustbe keptc...

Страница 4: ...may result GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes In absence of local codes install to the cur rent CAN1 B149 Ins...

Страница 5: ...wo leads to terminals 1 and 3 located on the gas valve Do not connect either the wall switch or the gas valve to electricity 110 volts or 24 volts INSTALLATION Clean out the ashes from the inside of t...

Страница 6: ...f 2 Set controls to high and light the unit 3 Wait 5 minutes Light a match and hold it to the spill tube opening 4 Venting action is satisfactory if smoke is drawn into the spill tube Venting action i...

Страница 7: ...oal embers glow when exposed to direct flame Use only certified PHAZERTM logs and char coal embers available from your Napoleon Wolf Steel Ltd dealer 1 Place the front log onto the main burner pushing...

Страница 8: ...et cover is formed with tabs to create a gap for air flow and must not be adjusted UPPER LOUVRES 3 PC SET A B C FIGUREA FIGUREB FIGURES C OPERA OPERA OPERA OPERA OPERATION MAINTENANCE TION MAINTENANCE...

Страница 9: ...ng the gas knob cannot be turned from pilot to off unless the knob is depressed 2 Turn off all electrical power to the stove 3 Turn the gas knob clockwise to off 4 Wait 5 minutes for any gas in the co...

Страница 10: ...to facilitate removal Remove the four screws holding the access door in place on the control assembly located to the back of the burner assembly FIGURE 18 Disconnect the electrical connectors at the b...

Страница 11: ...FLASHINGS 6 GI 945C 6 CHROME FLASHINGS 6 GI 945K 6 BLACK FLASHINGS 6 GI 950S 6 ALMOND ENAMEL FLASHINGS 6 GI 950B 6 BLUE ENAMEL FLASHINGS 6 GI 950K 6 BLACK ENAMEL FLASHINGS 6 GI 950F 6 GREEN ENAMEL FL...

Страница 12: ...6 6 PORCELAIN FLASHING KIT ALMOND GI 960B 6 6 PORCELAIN FLASHING KIT BLUE GI 960K 6 6 PORCELAIN FLASHING KIT BLACK GI 960F 6 6 PORCELAIN FLASHING KIT GREEN GI 960S 9 9 PORCELAIN FLASHING KIT ALMOND GI...

Страница 13: ...burning no gas to main burner gas knob is on wall switch is on heat flame adjustment valve is on if so equipped A Wall switch is defective connect a jumper wire across the wall switch terminals if the...

Страница 14: ...uc tions Exhaust fumes smelled in room head aches check for chimney blockage check that chimney is installed to building code room is in negative pressure increase fresh air supply Fireplace is spilli...

Страница 15: ...15 WS 415 44 11 17 99 NOTES NOTES NOTES NOTES NOTES...

Отзывы: