FUEL CONVERSION FOR MODEL
GDS60 / CDVS600
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • fax (705)720-9081 • www.napoleonfireplaces.com
WARNING: Failure to position the parts in accordance with
these diagrams or failure to use only parts specifically approved
with this appliance may result in property damage or personal
injury.
CAUTION: Before proceeding with conversion the gas supply
must be shut off prior to disconnecting the electrical power.
1. See the instruction manual to remove the cast front, glass
viewing door and log set.
2. Remove the log support / burner assembly by removing the 2
screws from the firebox back.
3. Using a deep
socket wrench,
remove the main
burner orifice. A
back-up wrench
must be used
on the manifold,
located below
the housing to
ensure that the
aluminium tubing does not twist or kink. Replace the burner
orifice supplied using pipe thread compound.
4. Remove the burner hood from the pilot assembly by pulling
vertically. Use an allen key to unscrew the injector. Replace the
pilot injector with the one supplied. Replace the pilot hood onto
the assembly ensuring key position for proper alignment.
5. Before replacing the burner assembly, adjust the burner shutter
opening to
5
/
16
” (7.9mm) for propane and
3
/
8
” (9.5mm) for natural
gas.
6. Replace and re-secure the log support/burner assembly
ensuring that the venturi fits over the burner orifice.
7. To convert the main valve to the desired fuel, follow the
instructions that are supplied with the SIT regulator assembly
kit.
8. The conversion data label must be filled out and attached
adjacent to the valve.
9. Turn on the gas supply and check for gas leaks by brushing
on a soap and water solution.
Do not use open flame.
10. Replace the log set. Then light the pilot and main burner to
ensure that the gas lines have been purged.
11. Replace the glass viewing door. Turn on the electrical
supply to the fireplace.
Purge all gas lines with the glass door off.
Assure that a continuous flow is at the burner before replacing
the door.
Kit W175-0138, Natural Gas to Propane Includes;
REGULATOR ASSEMBLY
1
#55 BURNER ORIFICE
- REAR VENT
1
#53 BURNER ORIFICE
- TOP VENT
1
CONVERSION DATA LABEL
1
PROPANE PILOT INJECTOR -
sit
1
Kit W175-0139, Propane to Natural Gas Includes;
REGULATOR ASSEMBLY
1
#45 BURNER ORIFICE
- REAR VENT
1
#35 BURNER ORIFICE
- TOP VENT
1
CONVERSION DATA LABEL
1
NATURAL GAS PILOT INJECTOR -
sit
1
These kits are for use at altitudes of 0 to 4500 feet.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the owner instructions supplied with the kit.
SCREWS
LOG SUPPORT / BURNER
ASSEMBLY
PILOT ASSEMBLY
BURNER ORIFICE
SIT
PILOT
HOOD
PILOT
INJECTER
W415-0993 / B / 10.20.16