Napoleon GDIZC - N Скачать руководство пользователя страница 1

1

W415-0223 / E / 03.05.09

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada 

t

 (705)721-1212 

t

 fax (705)722-6031

www.napoleonfireplaces.com 

t

[email protected]

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

GAS-FIRED DIRECT VENT INSERT

INSTALLATION AND OPERATION INSTRUCTIONS FOR:

VENTED GAS FIREPLACE HEATER

NATURAL GAS MODELS

 

GDIZC - N

PROPANE GAS MODELS

 

GDIZC - P

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS

WARNING: 

 If the information in these instructions is not followed exactly, a fi re or 

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of 

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch. 

 

•  Do not use any phone in your building.

Installation and service must be performed by a qualifi ed installer, service 

agency or the gas supplier.

•  Immediately call your gas supplier from 
a neighbour's phone. Follow the gas sup-
plier's instructions.
•  If you cannot reach your gas supplier, 
call the fi re department.

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS

Содержание GDIZC - N

Страница 1: ...ation in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapo...

Страница 2: ...insert Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace insert It is imperative that the control compartments burners and circulating blower and its p...

Страница 3: ...s used in the installation of the fireplace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to the following conditions During the first 10 y...

Страница 4: ...o conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachusetts State The fireplace damper m...

Страница 5: ...e of 1 inch or less may be drilled through the lower sides or bottom of the fireplace in a proper workman like manner This access hole must be plugged with non combustible insulation after the gas sup...

Страница 6: ...e intake it is necessary to adjust the primary air shutter See Air Shutter Settings on page 11 1 OUTSIDE Slip one end of a liner a minimum of 2 over one of the collars of the terminal Secure using 3 s...

Страница 7: ...kit complete with marquis trim may also be used to complete the installation These flashing and trim combinations are available in 6 and 9 inch widths as well as many finishes to accent any room decor...

Страница 8: ...the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the logs Care should be taken to shred the embers into thin small irregular pieces as...

Страница 9: ...ch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depart m...

Страница 10: ...pad Slide the blower into the clip C Secure to the threaded stud using the existing lock washer and wing nut Ensure that the blower does not touch the fireplace base or the firebox 6 Reconnect the tw...

Страница 11: ...e correct air shut ter setting Some vent configurations may display a very active flame If this appearance is not desirable the vent exit may be re stricted using the restrictor plate shown in FIGURE...

Страница 12: ...RCELAIN ENAMEL MAJOLICA BROWN 43 CISKF A CAST IRON SURROUND KIT PORCELAIN ENAMEL MAJOLICA GREEN 44 AK 4 ADAPTOR KIT FOR CAST IRON SURROUND 45 ANI K ANDIRON PAINTED BLACK 45 ANI G ANDIRON GOLD PLATED 1...

Страница 13: ...13 W415 0223 E 03 05 09 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 14: ...1 3 if the main burner lights check the wires for defects and or replace wires Faulty valve replace check that the manual valve is turned on check the pilot orifice for blockage replace the valve call...

Страница 15: ...lace glass cleaner DO NOT CLEAN GLASS WHEN HOT If deposits are not cleaned off regularly the glass may become permanently marked Main burner goes out pilot goes out REFER TO MAIN BURNER GOES OUT PILOT...

Страница 16: ...16 W415 0223 E 03 05 09 Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 43 1...

Отзывы: